Your browser doesn't support javascript.
loading
Electrosynthesis of Layered Organo-Manganese Dioxide Framework-Doped with Cobalt for Iodide Sensing.
Nakagawa, Kimiko; Suzuki, Kanon; Kondo, Misa; Hayakawa, Shinjiro; Nakayama, Masaharu.
Afiliación
  • Nakagawa K; Department of Applied Chemistry, Graduate School of Sciences and Technology for Innovation, Yamaguchi University , 2-16-1 Tokiwadai, Ube 755-8611, Japan.
  • Suzuki K; Department of Applied Chemistry, Graduate School of Sciences and Technology for Innovation, Yamaguchi University , 2-16-1 Tokiwadai, Ube 755-8611, Japan.
  • Kondo M; Department of Applied Chemistry, Graduate School of Engineering, Hiroshima University , 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan.
  • Hayakawa S; Department of Applied Chemistry, Graduate School of Engineering, Hiroshima University , 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan.
  • Nakayama M; Department of Applied Chemistry, Graduate School of Sciences and Technology for Innovation, Yamaguchi University , 2-16-1 Tokiwadai, Ube 755-8611, Japan.
Langmuir ; 33(19): 4647-4653, 2017 05 16.
Article en En | MEDLINE | ID: mdl-28464611
ABSTRACT
Aqueous Mn2+ ions were anodized at 70 °C with Co2+ in the presence of cationic surfactant, cetyltrimethylammonium (CTA). X-ray diffraction (XRD) analysis revealed that the deposited film possesses a layered structure of MnO2, the interlayer of which is occupied with the assembled CTA molecules. Inclusion of Co ions in the MnO2 film was evidenced by X-ray photoelectron spectroscopy (XPS). They were located in the MnO2 framework, not in the interlayer. The thus-obtained film, CTA-intercalated Co-framework-doped layered MnO2 (CTA/Co-MnO2), was applied as an electrochemical sensor toward iodide (I-), a hydrophobic anion. The organic phase between MnO2 layers could extract I- ions from solution, providing a better sensitivity than a film consisting of layered MnO2 with hydrated alkali metals. On the other hand, the Co-doped layers of MnO2 achieved faster electron transfer kinetics for the oxidation of I-, which resulted in a drastic reduction in response time compared to the nondoped CTA/MnO2.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Langmuir Asunto de la revista: QUIMICA Año: 2017 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Langmuir Asunto de la revista: QUIMICA Año: 2017 Tipo del documento: Article País de afiliación: Japón