Your browser doesn't support javascript.
loading
A fit-for-purpose method to monitor 16 European Union PAHs in food: results of five years of official food control in two Italian regions.
Lestingi, Carmela; Tavoloni, Tamara; Bardeggia, Valentina; Perugini, Monia; Piersanti, Arianna.
Afiliación
  • Lestingi C; a Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche , Laboratorio Controllo Chimico e Biomonitoraggio , Ancona , Italy.
  • Tavoloni T; a Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche , Laboratorio Controllo Chimico e Biomonitoraggio , Ancona , Italy.
  • Bardeggia V; a Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche , Laboratorio Controllo Chimico e Biomonitoraggio , Ancona , Italy.
  • Perugini M; b Università degli Studi di Teramo , Facoltà di Bioscienze e Tecnologie Agroalimentari ed Ambientali , Teramo , Italy.
  • Piersanti A; a Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche , Laboratorio Controllo Chimico e Biomonitoraggio , Ancona , Italy.
Article en En | MEDLINE | ID: mdl-28513332
ABSTRACT
A gas-chromatographic single-quadrupole analytical method for the analysis of the 16 priority European Union (EU) polycyclic aromatic hydrocarbons (PAHs) in food is presented. The method fulfils the request of Regulation EU 836/2011 for an analytical procedure to be used for official control of PAHs in food in EU member states. The sample preparation involves a pressurised liquid extraction (PLE) with an in-cell clean-up step followed by a lipid removal using solid-phase extraction (SPE) on a styrene divinylbenzene stationary phase (SDVB) and a final gel-permeation chromatography (GPC) step. To reach a better sensitivity for all the analytes, including the heaviest last eluting PAHs, 3 µl of the purified extract were injected in solvent vent mode using a programmable temperature vaporization (PTV) injector. The isobaric PAH isomers were successfully separated using an Agilent Technologies DB-17MS (20 m × 0.18 mm × 0.18 µm) column. The method was fully validated using an in-house approach and the sensitivity, accuracy and precision obtained were satisfactory. The method expanded uncertainty was estimated and it was verified that it was below the maximum standard measurement uncertainty. Moreover, the results of 347 samples of meat and meat products, fish and fish products and mussels collected from January 2012 to December 2016 in the Marche and Umbria regions of Italy are reported. None of the samples exceed the maximum levels fixed by EU Regulation 835/2011, and clams turned out to be the most contaminated among the food matrices analysed. Finally, an estimate of the sum of four marker PAHs (benzo[a]anthracene, benzo[b]fluoranthene, benzo[a]pyrene, chrysene) as indicator of the PAHs contamination was done by comparison with the 16 carcinogenic PAHs sum.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hidrocarburos Policíclicos Aromáticos / Contaminación de Alimentos País/Región como asunto: Europa Idioma: En Revista: Food Addit Contam Part A Chem Anal Control Expo Risk Assess Asunto de la revista: CIENCIAS DA NUTRICAO Año: 2017 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hidrocarburos Policíclicos Aromáticos / Contaminación de Alimentos País/Región como asunto: Europa Idioma: En Revista: Food Addit Contam Part A Chem Anal Control Expo Risk Assess Asunto de la revista: CIENCIAS DA NUTRICAO Año: 2017 Tipo del documento: Article País de afiliación: Italia