Valvulo-arterial impedance (Zva) has been shown to predict worse outcome in medically managed aortic stenosis (AS) patients. We aimed to investigate the association between Zva and left ventricular (LV) adaptation and to explore the predictive value of Zva for cardiac functional recovery and outcome after transcatheter aortic valve replacement (TAVR). We prospectively enrolled 128 patients with AS who underwent TAVR. Zva was calculated as: (systolic blood pressure + mean transaortic gradient)/stroke volume index). Echocardiographic assessment occurred at baseline, 1-month and 1-year after TAVR. The primary endpoints were to investigate associations between Zva and global longitudinal strain (GLS) at baseline as well as GLS change after TAVR. The secondary was to compare all-cause mortality after TAVR between patients with pre-defined Zva (=5 mmHg m2/ml), stroke volume index (=35 ml/m2), and GLS (=-15%) cutoffs. The mean GLS was reduced (-13.0 ± 3.2%). The mean Zva was 5.2 ± 1.6 mmHg*m2/ml with 55% of values ≥5.0 mmHg*m2/ml, considered to be abnormally high. Higher Zva correlated with worse GLS (r = -0.33, p < 0.001). After TAVR, Zva decreased significantly (5.1 ± 1.6 vs. 4.5 ± 1.6 mmHg*m2/ml, p = 0.001). A reduction of Zva at 1-month was associated with GLS improvement at 1-month (r = -0.31, p = 0.001) and at 1-year (r = -0.36 and p = 0.001). By Kaplan-Meier analysis, patients with higher Zva at baseline had higher mortality (Log-rank p = 0.046), while stroke volume index and GLS did not differentiate outcome (Log-rank p = 0.09 and 0.25, respectively). As a conclusion, Zva is correlated with GLS in AS as well as GLS improvement after TAVR. Furthermore, a high baseline Zva may have an additional impact to traditional parameters on predicting worse mortality after TAVR.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Aorta
/
Válvula Aórtica
/
Estenosis de la Válvula Aórtica
/
Función Ventricular Izquierda
/
Presión Arterial
/
Reemplazo de la Válvula Aórtica Transcatéter
Tipo de estudio:
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Int J Cardiovasc Imaging
Asunto de la revista:
DIAGNOSTICO POR IMAGEM
Año:
2017
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos