Your browser doesn't support javascript.
loading
Results at a minimum follow-up of 5 years of a ligaments-compatible total ankle replacement design.
Giannini, Sandro; Romagnoli, Matteo; Barbadoro, Paolo; Marcheggiani Muccioli, Giulio Maria; Cadossi, Matteo; Grassi, Alberto; Zaffagnini, Stefano.
Afiliación
  • Giannini S; Department of Orthopaedic Surgery, Istituto Ortopedico Rizzoli, Bologna, Italy.
  • Romagnoli M; Department of Orthopaedic Surgery, Dipartimento Rizzoli Sicilia, Istituto Ortopedico Rizzoli, Bagheria, Italy. Electronic address: matteo.romagnoli@ior.it.
  • Barbadoro P; Department of Orthopaedic Surgery, Istituto Ortopedico Rizzoli, Bologna, Italy.
  • Marcheggiani Muccioli GM; Department of Orthopaedic Surgery, Dipartimento Rizzoli Sicilia, Istituto Ortopedico Rizzoli, Bagheria, Italy.
  • Cadossi M; Department of Orthopaedic Surgery, Istituto Ortopedico Rizzoli, Bologna, Italy.
  • Grassi A; Department of Orthopaedic Surgery, Dipartimento Rizzoli Sicilia, Istituto Ortopedico Rizzoli, Bagheria, Italy.
  • Zaffagnini S; Department of Orthopaedic Surgery, Dipartimento Rizzoli Sicilia, Istituto Ortopedico Rizzoli, Bagheria, Italy.
Foot Ankle Surg ; 23(2): 116-121, 2017 Jun.
Article en En | MEDLINE | ID: mdl-28578794
ABSTRACT

BACKGROUND:

A new design of 3-part ankle replacement was developed to achieve compatibility with the natural ligaments by allowing certain fibers to remain isometric during passive motion.

METHODS:

We evaluate 75 ankle prostheses implanted from July 2003 to December 2008, at a mean follow-up 6.5±1.1years (range 5-9 years). The mean age at surgery was 62±13years (range 29-82).

RESULTS:

The mean AOFAS scores achieved at pre-op and at last follow-up were respectively 37±5 (23-45) and 78±8 (64-98). (p<0.001). Clinical range of motion of the ankle measured by goniometer pre op was 1°±2 of dorsiflexion and 12°±4° of plantarflexion; at last follow-up range of motion increased to 6°±5° in dorsiflexion (p<0.01) and 18°±7° in plantarflexion (p<0.05). Radiographs showed no loosening and little signs of radiolucency. Two revisions necessitated component removal, neither for implant loosening. The overall survival rate was 97.3%.

CONCLUSIONS:

Function and Range-of-motion showed significant improvements. These results demonstrate that ligaments-compatible shaped talar and tibial components, with a fully conforming interposed meniscal bearing, can provide satisfactory survival rates and clinical outcomes in the middle term.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoartritis / Artritis Reumatoide / Artroplastia de Reemplazo de Tobillo / Prótesis Articulares / Ligamentos Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Foot Ankle Surg Asunto de la revista: ORTOPEDIA Año: 2017 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoartritis / Artritis Reumatoide / Artroplastia de Reemplazo de Tobillo / Prótesis Articulares / Ligamentos Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Foot Ankle Surg Asunto de la revista: ORTOPEDIA Año: 2017 Tipo del documento: Article País de afiliación: Italia