Your browser doesn't support javascript.
loading
Fibrinogen Reduction During Selective Plasma Exchange due to Membrane Fouling.
Ohkubo, Atsushi; Okado, Tomokazu; Miyamoto, Satoko; Hashimoto, Yurie; Komori, Shigeto; Yamamoto, Motoki; Maeda, Takuma; Itagaki, Ayako; Yamamoto, Hiroko; Seshima, Hiroshi; Kurashima, Naoki; Iimori, Soichiro; Naito, Shotaro; Sohara, Eisei; Uchida, Shinichi; Rai, Tatemitsu.
Afiliación
  • Ohkubo A; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Okado T; Department of Nephrology, Tokyo Medical and Dental University, Tokyo, Japan.
  • Miyamoto S; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Hashimoto Y; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Komori S; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Yamamoto M; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Maeda T; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Itagaki A; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Yamamoto H; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Seshima H; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Kurashima N; Medical Engineering Center, Medical Hospital of Tokyo Medical and Dental University, Tokyo, Japan.
  • Iimori S; Department of Nephrology, Tokyo Medical and Dental University, Tokyo, Japan.
  • Naito S; Department of Nephrology, Tokyo Medical and Dental University, Tokyo, Japan.
  • Sohara E; Department of Nephrology, Tokyo Medical and Dental University, Tokyo, Japan.
  • Uchida S; Department of Nephrology, Tokyo Medical and Dental University, Tokyo, Japan.
  • Rai T; Department of Nephrology, Tokyo Medical and Dental University, Tokyo, Japan.
Ther Apher Dial ; 21(3): 232-237, 2017 Jun.
Article en En | MEDLINE | ID: mdl-28661096
ABSTRACT
Fibrinogen is substantially reduced by most plasmapheresis modalities but retained in selective plasma exchange using Evacure EC-4A10 (EC-4A). Although EC-4A's fibrinogen sieving coefficient is 0, a session of selective plasma exchange reduced fibrinogen by approximately 19%. Here, we investigated sieving coefficient in five patients. When the mean processed plasma volume was 1.15 × plasma volume, the mean reduction of fibrinogen during selective plasma exchange was approximately 15%. Fibrinogen sieving coefficient was 0 when the processed plasma volume was 1.0 L, increasing to 0.07 when the processed plasma volume was 3.0 L, with a mean of 0.03 during selective plasma exchange. When fibrinogen sieving coefficient was 0, selective plasma exchange reduced fibrinogen by approximately 10%. Scanning electron microscopy images revealed internal fouling of EC-4A's hollow fiber membrane by substances such as fibrinogen fibrils. Thus, fibrinogen reduction by selective plasma exchange may be predominantly caused by membrane fouling rather than filtration.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Intercambio Plasmático / Fibrinógeno / Enfermedades del Sistema Inmune / Membranas Artificiales Tipo de estudio: Observational_studies Límite: Adult / Humans / Male / Middle aged Idioma: En Revista: Ther Apher Dial Asunto de la revista: HEMATOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Intercambio Plasmático / Fibrinógeno / Enfermedades del Sistema Inmune / Membranas Artificiales Tipo de estudio: Observational_studies Límite: Adult / Humans / Male / Middle aged Idioma: En Revista: Ther Apher Dial Asunto de la revista: HEMATOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Japón