In vivo hip joint loads and pedal forces during ergometer cycling.
Damm, P; Dymke, J; Bender, A; Duda, G; Bergmann, G.
Afiliación
  • Damm P; Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany. Electronic address: philipp.damm@charite.de.
  • Dymke J; Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Bender A; Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Duda G; Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Bergmann G; Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany.
J Biomech ; 60: 197-202, 2017 07 26.
Article en En | MEDLINE | ID: mdl-28709659
The rising prevalence of osteoarthritis and an increase in total hip replacements calls for attention to potential therapeutic activities. Cycling is considered as a low impact exercise for the hip joint and hence recommended. However, there are limited data about hip joint loading to support this claim. The aim of this study was to measure synchronously the in vivo hip joint loads and pedal forces during cycling. The in vivo hip joint loads were measured in 5 patients with instrumented hip implants. Data were collected at several combinations of power and cadence, at two saddle heights. Joint loads and pedal forces showed strong linear correlation with power. So the relationship between the external pedal forces and internal joint forces was shown. While cycling at different cadences the minimum joint loads were acquired at 60RPM. The lower saddle height configuration results in an approximately 15% increase compared to normal saddle height. The results offered new insights into the actual effects of cycling on the hip joint and can serve as useful tools while developing an optimum cycling regimen for individuals with coxarthrosis or following total hip arthroplasty. Due to the relatively low contact forces, cycling at a moderate power level of 90W at a normal saddle height is suitable for patients.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ciclismo / Artroplastia de Reemplazo de Cadera / Articulación de la Cadera Tipo de estudio: Risk_factors_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: J Biomech Año: 2017 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ciclismo / Artroplastia de Reemplazo de Cadera / Articulación de la Cadera Tipo de estudio: Risk_factors_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: J Biomech Año: 2017 Tipo del documento: Article Pais de publicación: Estados Unidos