Randomized, noninferiority study between video versus hand ultrasound with wet foam dressing materials to simulate B-lines in lung ultrasound: A CONSORT-compliant article.
Park, Eun Jung; Yoon, Young Tak; Hong, Chong Kun; Ha, Young Rock; Ahn, Jung Hwan.
Afiliación
  • Park EJ; Department of Emergency Medicine, Ajou University School of Medicine, Suwon Department of Emergency Medicine, Bundang Jesaeng General Hospital, Sungnam-si, Republic of Korea.
Medicine (Baltimore) ; 96(30): e7642, 2017 Jul.
Article en En | MEDLINE | ID: mdl-28746228
ABSTRACT

BACKGROUND:

This study evaluated the efficacy of a teaching method using simulated B-lines of hand ultrasound with a wet foam dressing material.

METHODS:

This prospective, randomized, noninferiority study was conducted on emergency medical technician students without any relevant training in ultrasound. Following a lecture including simulated (SG) or real video clips (RG) of B-lines, a posttest was conducted and a retention test was performed after 2 months. The test consisted of questions about B-lines in 40 randomly mixed video clips (20 simulated and 20 real videos) with 4 answer scores (R-1 [the correct answer score for the real video clips] vs S-1 [the correct answer score for the simulated video clips] in the posttest, R-2 [the correct answer score for the real video clips] vs S-2 [the correct answer score for the simulated video clips] in the retention test).

RESULTS:

A total of 77 and 73 volunteers participated in the posttest (RG, 38; SG, 39) and retention test (RG, 36; SG, 37), respectively. There was no significant (P > .05) difference in scores of R-1, S-1, R-2, or S-2 between RG and SG. The mean score differences between RG and SG were -0.6 (95% confidence interval [CI] -1.49 to 0.11) in R-1, -0.1 (95% CI -1.04 to 0.86) in S-1, 0 (95% CI -1.57 to 1.50) in R-2, and -0.2 (95% CI -1.52 to 0.25) in S-2. The mean differences and 95% CIs for all parameters fell within the noninferiority margin of 2 points (10%).

CONCLUSION:

Simulated B-lines of hand ultrasound with a wet foam dressing material were not inferior to real B-lines. They were effective for teaching and simulations. TRIAL REGISTRATION The study was registered with the Clinical Trial Registry of Korea https//cris.nih.go.kr/cris/index.jsp (KCT0002144).
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Grabación en Video / Ultrasonografía / Auxiliares de Urgencia / Pulmón / Modelos Anatómicos Tipo de estudio: Clinical_trials / Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Medicine (Baltimore) Año: 2017 Tipo del documento: Article Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Grabación en Video / Ultrasonografía / Auxiliares de Urgencia / Pulmón / Modelos Anatómicos Tipo de estudio: Clinical_trials / Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Medicine (Baltimore) Año: 2017 Tipo del documento: Article Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA