Your browser doesn't support javascript.
loading
A preliminary evaluation study of new generation multiplex STR kits comprising of the CODIS core loci and the European Standard Set loci.
Tan, Jolena Ying Ying; Tan, Yuen Peng; Ng, Shilen; Tay, Annabel Suan; Phua, Yong Han; Tan, Wei Jie; Ong, Terenze Yao Rui; Chua, Li Min; Syn, Christopher Kiu Choong.
Afiliación
  • Tan JYY; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore. Electronic address: jolena_tan@hsa.gov.sg.
  • Tan YP; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
  • Ng S; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
  • Tay AS; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
  • Phua YH; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
  • Tan WJ; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
  • Ong TYR; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
  • Chua LM; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
  • Syn CKC; DNA Profiling Laboratory, Applied Sciences Group, Health Sciences Authority, 11 Outram Road, 169078, Singapore.
J Forensic Leg Med ; 52: 16-23, 2017 Nov.
Article en En | MEDLINE | ID: mdl-28797659
ABSTRACT
The GlobalFiler™ (Life Technologies), Investigator® 24plex QS (Qiagen), and PowerPlex® Fusion 6C (Promega) kits are the latest generation 6-dye fluorescent chemistry STR-PCR amplification kits. These kits allow for the simultaneous amplification of the CODIS core loci and the European Standard Set loci, as well as a few Y-STR loci in addition to the standard sex-determining marker Amelogenin. The present study was designed to be a preliminary evaluation of the three STR-PCR kits in terms of sensitivity, profile recovery from degraded DNA samples, tolerance to PCR inhibitors, and detection of minor components in DNA mixtures. The results showed that the three STR-PCR kits had relatively similar performance with each kit faring better for the different aspects studied. The PowerPlex® Fusion 6C and the Investigator® 24plex QS kits were shown to tolerate inhibitors better, while the GlobalFiler™ kit appeared to have a higher mean percentage recovery of alleles from low template DNA samples and for minor components in DNA mixtures.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reacción en Cadena de la Polimerasa / Dermatoglifia del ADN / Repeticiones de Microsatélite Tipo de estudio: Evaluation_studies Límite: Female / Humans / Male Idioma: En Revista: J Forensic Leg Med Asunto de la revista: JURISPRUDENCIA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reacción en Cadena de la Polimerasa / Dermatoglifia del ADN / Repeticiones de Microsatélite Tipo de estudio: Evaluation_studies Límite: Female / Humans / Male Idioma: En Revista: J Forensic Leg Med Asunto de la revista: JURISPRUDENCIA Año: 2017 Tipo del documento: Article