Your browser doesn't support javascript.
loading
Versatile chromatographic method for catechin determination in development of topical formulations containing natural extracts.
Ferreira-Nunes, Ricardo; Angelo, Tamara; da Silva, Sandra Márcia Mazutti; Magalhães, Pérola Oliveira; Gratieri, Tais; da Cunha-Filho, Marcílio Sérgio Soares; Gelfuso, Guilherme Martins.
Afiliación
  • Ferreira-Nunes R; Laboratory of Food, Drugs and Cosmetics (LTMAC), School of Health Sciences, University of Brasília, 70.910-900, Brasília, DF, Brazil.
  • Angelo T; Laboratory of Food, Drugs and Cosmetics (LTMAC), School of Health Sciences, University of Brasília, 70.910-900, Brasília, DF, Brazil.
  • da Silva SMM; Laboratório de Produtos Naturais, School of Health Sciences, University of Brasília, 70.910-900, Brasília, DF, Brazil.
  • Magalhães PO; Laboratório de Produtos Naturais, School of Health Sciences, University of Brasília, 70.910-900, Brasília, DF, Brazil.
  • Gratieri T; Laboratory of Food, Drugs and Cosmetics (LTMAC), School of Health Sciences, University of Brasília, 70.910-900, Brasília, DF, Brazil.
  • da Cunha-Filho MSS; Laboratory of Food, Drugs and Cosmetics (LTMAC), School of Health Sciences, University of Brasília, 70.910-900, Brasília, DF, Brazil.
  • Gelfuso GM; Laboratory of Food, Drugs and Cosmetics (LTMAC), School of Health Sciences, University of Brasília, 70.910-900, Brasília, DF, Brazil.
Biomed Chromatogr ; 32(2)2018 Feb.
Article en En | MEDLINE | ID: mdl-28809050
ABSTRACT
Catechin is found in several natural sources, as Eugenia dysenterica and Syzygium cumini extracts. Its antioxidant and UV-protective properties suggest a potential use in cosmetic and dermatological formulations. A simple analytical method capable of giving support to experiments performed along the development of topical formulations containing this natural substance (i.e. drug assay, skin permeation and stability studies), however, is still needed. Thus, this work aimed to develop and validate a selective HPLC method for catechin determination during the development of topical formulations. Separation was achieved using an RP-C18 column (300 × 3.9 mm; 10 µm), with a mobile phase of methanol-phosphoric acid 0.01 m (15 85, v/v), a flow rate of 0.8 mL/min, temperature set at 40°C and UV detection at 230 nm. The method was linear in a range from 0.5 to 10.0 µg/mL (r = 0.9998), precise with an overall variation coefficient of 5.5% and accurate with catechin recovery from the skin layers >85%. Additionally, the method was sensitive (limit of detection, 0.109 µg/mL; limit of quantification, 0.342 µg/mL) and selective against plant extracts, skin matrices and formulation interferents, as well as catechin degradation products. It was also robust regarding both methodology parameters and analytical stability.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Extractos Vegetales / Catequina / Cromatografía Líquida de Alta Presión Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Biomed Chromatogr Año: 2018 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Extractos Vegetales / Catequina / Cromatografía Líquida de Alta Presión Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Biomed Chromatogr Año: 2018 Tipo del documento: Article País de afiliación: Brasil
...