A New Experimental Device for Transapical Access of the Aortic and Mitral Valves as well as the Aorta in its Various Segments.
Paim, Leonardo; Fonseca, José Honório Palma da; Arruda, Francismar Vidal de; Gutierrez, Paulo Sampaio; Moreira, Luiz Felipe Pinho; Jatene, Fabio Biscegli.
Afiliación
  • Paim L; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InCor-HCFMUSP), São Paulo, SP, Brazil.
  • Fonseca JHPD; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InCor-HCFMUSP), São Paulo, SP, Brazil.
  • Arruda FV; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InCor-HCFMUSP), São Paulo, SP, Brazil.
  • Gutierrez PS; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InCor-HCFMUSP), São Paulo, SP, Brazil.
  • Moreira LFP; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InCor-HCFMUSP), São Paulo, SP, Brazil.
  • Jatene FB; Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InCor-HCFMUSP), São Paulo, SP, Brazil.
Braz J Cardiovasc Surg ; 32(3): 156-161, 2017.
Article en En | MEDLINE | ID: mdl-28832792
OBJECTIVE:: To present the results of a new experimental device developed to facilitate the transapical access in endovascular treatment of structural heart diseases. It aims to reduce the risk of bleeding and complications in this type of access and demonstrate the device as a safe, fast and effective alternative. METHODS:: CorPoint is composed of three parts: introducer, base with coiled spring, and closing capsule. By rotating movements, the spring is introduced into the myocardium and progressively approaches the base to the surface of the heart. Guidewires and catheters are inserted through the hollow central part and, at the end of the procedure, the capsule is screwed over the base, therefore stopping any bleeding. RESULTS:: The device was implanted in 15 pigs, weighing 60 kg each, through an anterolateral thoracotomy, while catheters were introduced and guided by fluoroscopy. All animals had minimal bleeding; introducers with diameter up to 22 Fr were used and various catheters and guidewires were easily handled. After finishing the procedure, the closing capsule was attached and no bleeding was observed at the site. CONCLUSION:: This new device has proved effective, fast and secure for the transapical access. This shows great potential for use, especially by ensuring an easier and direct access to the mitral and aortic valves; the shortest distance to be traveled by catheters; access to the ascending and descending aorta; decreased bleeding complications; decreased surgical time; and the possibility of allowing the technique to evolve and become totally percutaneous.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Cateterismo Cardíaco / Diseño de Equipo / Reemplazo de la Válvula Aórtica Transcatéter / Ventrículos Cardíacos / Válvula Mitral Tipo de estudio: Etiology_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Braz J Cardiovasc Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Cateterismo Cardíaco / Diseño de Equipo / Reemplazo de la Válvula Aórtica Transcatéter / Ventrículos Cardíacos / Válvula Mitral Tipo de estudio: Etiology_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Braz J Cardiovasc Surg Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil