Your browser doesn't support javascript.
loading
Investigation of γ-γ coincidence counting using the National Nuclear Array (NANA) as a primary standard.
Collins, S M; Shearman, R; Keightley, J D; Regan, P H.
Afiliación
  • Collins SM; National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom; Department of Physics, University of Surrey, Guildford GU2 7XH, United Kingdom. Electronic address: sean.collins@npl.co.uk.
  • Shearman R; National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom; Department of Physics, University of Surrey, Guildford GU2 7XH, United Kingdom.
  • Keightley JD; National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom.
  • Regan PH; National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom; Department of Physics, University of Surrey, Guildford GU2 7XH, United Kingdom.
Appl Radiat Isot ; 134: 290-296, 2018 Apr.
Article en En | MEDLINE | ID: mdl-28843735
The National Physical Laboratory has recently been in the process of commissioning a multi-detector γ ray array - the National Nuclear Array (NANA). In this study we have sought to exploit the NANA and the excellent timing characteristics of its intrinsic LaBr3(Ce) scintillation detectors for use as a primary standardisation system. For this initial investigation, the absolute standardisation of 60Co has been performed by the γ-γ coincidence technique using NANA and the result compared to the established 4π(LS)-γ Digital Coincidence Counting (DCC) system. The effect of the angular correlation of the stretched E2 transitions emitted from the 4+→2+→0 states of 60Ni on the activity determined by NANA was observed between the pairs of detectors. Corrections for these angular correlations were derived through Monte Carlo simulations. An activity per unit mass by NANA of 330.8 (10) kBqg-1 for the 60Co solution was determined. There was no significant statistical difference between the results of NANA and the 4π(LS)-γ DCC, with a relative difference of 0.04% observed. This study shows that NANA can be used as a primary standard.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Appl Radiat Isot Asunto de la revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Año: 2018 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Appl Radiat Isot Asunto de la revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Año: 2018 Tipo del documento: Article Pais de publicación: Reino Unido