Your browser doesn't support javascript.
loading
Rapid and sensitive serum glucose determination using chemical labeling coupled with black phosphorus-assisted laser desorption/ionization time-of-flight mass spectrometry.
Wang, Qing; Yu, Lei; Qi, Chu-Bo; Ding, Jun; He, Xiao-Mei; Wang, Ren-Qi; Feng, Yu-Qi.
Afiliación
  • Wang Q; Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, People's Republic of China.
  • Yu L; Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, People's Republic of China.
  • Qi CB; Department of Pathology, Hubei Cancer Hospital, Wuhan, Hubei 430079, People's Republic of China.
  • Ding J; Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, People's Republic of China.
  • He XM; Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, People's Republic of China.
  • Wang RQ; Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, People's Republic of China; College of Chemistry and Chemical Engineering, Lanzhou, Gansu 730000, People's Republic of China.
  • Feng YQ; Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, People's Republic of China. Electronic address: yqfeng@whu.edu.cn.
Talanta ; 176: 344-349, 2018 Jan 01.
Article en En | MEDLINE | ID: mdl-28917760
ABSTRACT
Monitoring the concentration of blood glucose in patients is a key component of good medical diagnoses. Therefore, developing an accurate, rapid and sensitive strategy for monitoring blood glucose is of vital importance. We proposed a strategy for serum glucose determination combining 2-(4-boronobenzyl) isoquinolin-2-ium bromide chemical labeling with black phosphorus assisted laser desorption ionization-time of flight mass spectrometry (CL-BP/ALDI-TOF MS). The entire analytical process consisted of 1min of protein precipitation and 3min of chemical labeling in a microwave oven prior to the BP/ALDI-TOF MS analysis. The analysis can be completed in 5min with high throughput and extremely low sample consumption. Good linearity for glucose was obtained with a correlation coefficient (R) of 0.9986. The limit of detection (LOD) and limit of quantification (LOQ) were 11.5 fmol and 37.5 fmol, respectively. Satisfied reproducibility and reliability were gained by evaluation of the intra- and inter-day precisions with relative standard deviations (RSDs) less than 7.2% and relative recoveries ranging from 87.1% to 108.1%, respectively. The proposed strategy was also applied for the analysis of endogenous glucose in various serum samples and the results were consistent with those obtained using the hexokinase method in a clinical laboratory. Considering the results, the proposed CL-BP/ALDI-TOF MS strategy has proven to be reliable, fast, and sensitive for quantitative analysis of serum glucose.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glucemia / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Talanta Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glucemia / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Talanta Año: 2018 Tipo del documento: Article