Your browser doesn't support javascript.
loading
[Intracranial Pressure Evaluation by Ophthalmologist]. / Hodnotenie intrakraniálneho tlaku oftalmológom.
Cesk Slov Oftalmol ; 73(2): 57-60, 2017.
Article en Cs | MEDLINE | ID: mdl-28931297
ABSTRACT
The value of ICT is important in diagnosis of the diseases of the eye and orbit Methods for direct measurement of intracranial pressure (ICT) are exact, but they are invasive and there is some risk of infection and damage of the tissue. Currently there are 2 valid indirect methods of mesurement of IKT. Digital Ophthalmodynamometry (D-ODM) and Transcranial Doppler ultrasonography (TDU). D-ODM is a non-invasive method for measuring of the Pulsating Venous Pressure (VPT). We can measure VPT by the pulse phenomena. Physiologically (to be maintained blood flow) VPT not be less than the ICT and intraorbital pressure (IorbitT). If we raise the VPT to compensate the current IKT (or IorbitT) - there is a pulsation VCR. We can calculate aproxymative IKT with the formula IKT = 0.903 - (VPT) - 8.87, or IKT = 0.29 + 0.74 (VOT / PI (AO)). [VOT = intraocular pressure. PI - pulsatility index arteriae ophthalmic from Color Doppler ultrasonography.] IKT can be approximate calculate with mathematical formulas IKT = 055 × BMI (kg / m2) + 0.16 × KTD (mmHg) - 018 x age (years) - 1.91. [KTD - diastolic blood pressure, BMI - Body master index] or IKT = 16.95 x 0.39 x OSASW09 + BMI + 0.14 + TKS - 20.90. [OSASW095 width of the orbital arachnoid space at a distance of 9 mm behind the eyeball (nuclear magnetic resonance). BMI Body Mass Index. TKS mean arterial pressure]. Normal values of VPT are under 15 torr. The risk of increased intracranial pressure is above 20 torr. Under physiological conditions, there is intraocular pressure lower in about 5 torr than VPT.

CONCLUSION:

D-ODM is a useful screening method in the evaluation of IKT for hydrocephalus, brain tumors, cerebral hemorrhage after brain trauma and also in ocular diseases Glaucoma, Ocular hypertension, orbitopathy (endocrine orbitopathy), ischemic / non-ischemic occlusion of blood vessels of the eye, indirect detection ICT carotid artery-cavernous fistula, amaurosis fugax, optic neuropathy. D-ODM is suitable for immediate evaluation of IKT, but is not suitable for continuous monitoring. As it can be repeated, it is useful for a patient suspected of having an increased ICT.Key words central retinal artery, central retinal vein, colour Doppler ultrasonography, digital ophthalmodynamometry, intracranial pressure, pressure of cerebrospinal fluid, transcranial Doppler ultrasonography, intraocular pressure, venous pulsation pressure, venous outflow pressure, retinal venous pressure.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Presión Intracraneal / Glaucoma / Oftalmólogos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: Cs Revista: Cesk Slov Oftalmol Asunto de la revista: OFTALMOLOGIA Año: 2017 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Presión Intracraneal / Glaucoma / Oftalmólogos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: Cs Revista: Cesk Slov Oftalmol Asunto de la revista: OFTALMOLOGIA Año: 2017 Tipo del documento: Article