Your browser doesn't support javascript.
loading
Sonographic assessment of volaemia: development and validation of a new method in dogs.
Cambournac, M; Goy-Thollot, I; Violé, A; Boisvineau, C; Pouzot-Nevoret, C; Barthélemy, A.
Afiliación
  • Cambournac M; Intensive Care Unit (SIAMU), Université de Lyon, VetAgro Sup, APCSe, F-69280, Marcy l'Etoile, France.
  • Goy-Thollot I; Intensive Care Unit (SIAMU), Université de Lyon, VetAgro Sup, APCSe, F-69280, Marcy l'Etoile, France.
  • Violé A; Intensive Care Unit (SIAMU), Université de Lyon, VetAgro Sup, APCSe, F-69280, Marcy l'Etoile, France.
  • Boisvineau C; Intensive Care Unit (SIAMU), Université de Lyon, VetAgro Sup, APCSe, F-69280, Marcy l'Etoile, France.
  • Pouzot-Nevoret C; Intensive Care Unit (SIAMU), Université de Lyon, VetAgro Sup, APCSe, F-69280, Marcy l'Etoile, France.
  • Barthélemy A; Intensive Care Unit (SIAMU), Université de Lyon, VetAgro Sup, APCSe, F-69280, Marcy l'Etoile, France.
J Small Anim Pract ; 59(3): 174-182, 2018 03.
Article en En | MEDLINE | ID: mdl-28960319
ABSTRACT

OBJECTIVES:

The aims of this study were to describe a method for the sonographic assessment of volaemia, to determinate inter- and intra-operator variability and to assess the ability to detect blood loss after blood donation in healthy dogs. MATERIALS AND

METHODS:

The left kidney was identified in a spleno-renal view, and transverse views of the caudal vena cava and aorta were obtained in 12 dogs. Vessel diameters were measured in B-mode, in duplicate by two operators, and the caudal vena cavaaorta ratio was calculated. Intra- and inter-operator variabilities were assessed using a Bland-Altman method by plotting the differences between the repeated measurements obtained from the same subject by the same operator and by the two operators against their means. Before and after blood donation measurements were compared using paired t-tests or one-sample t-tests, if appropriate.

RESULTS:

Intra- and inter-operator variability was within the limit of agreement for the vast majority of measurements. After a blood donation of 9·8 ±2·2 mL/kg, the mean aorta measurements were not significantly different from those obtained before blood donation (1·11 versus 1·10, P=0·28), whereas the mean caudal vena cava measurements and caudal vena cavaaorta ratios were significantly lower (1·28 versus 1·01, P<0·0001; 1·17 versus 1·01, P=0·0001, respectively). CLINICAL

SIGNIFICANCE:

The low intra- and inter-operator variabilities in the caudal vena cava, aorta and caudal vena cavaaorta ratio measurements support their reliability and operator independency. The sonographic assessment of volaemia appears to be a promising non-invasive, repeatable point-of-care ultrasound protocol for assessment and monitoring of blood loss. Further studies are needed to assess the sonographic assessment of volaemia protocol in spontaneously bleeding dogs.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta / Vena Cava Inferior / Donantes de Sangre / Volumen Sanguíneo / Perros Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Límite: Animals Idioma: En Revista: J Small Anim Pract Año: 2018 Tipo del documento: Article País de afiliación: Francia Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta / Vena Cava Inferior / Donantes de Sangre / Volumen Sanguíneo / Perros Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Límite: Animals Idioma: En Revista: J Small Anim Pract Año: 2018 Tipo del documento: Article País de afiliación: Francia Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM