Your browser doesn't support javascript.
loading
Giant light-harvesting nanoantenna for single-molecule detection in ambient light.
Trofymchuk, Kateryna; Reisch, Andreas; Didier, Pascal; Fras, François; Gilliot, Pierre; Mely, Yves; Klymchenko, Andrey S.
Afiliación
  • Trofymchuk K; Université de Strasbourg, Laboratoire de Biophotonique et Pharmacologie, UMR 7213 CNRS, Faculté de Pharmacie, 74, Route du Rhin, F-67401 ILLKIRCH, France.
  • Reisch A; Université de Strasbourg, Laboratoire de Biophotonique et Pharmacologie, UMR 7213 CNRS, Faculté de Pharmacie, 74, Route du Rhin, F-67401 ILLKIRCH, France.
  • Didier P; Université de Strasbourg, Laboratoire de Biophotonique et Pharmacologie, UMR 7213 CNRS, Faculté de Pharmacie, 74, Route du Rhin, F-67401 ILLKIRCH, France.
  • Fras F; CNRS, IPCMS, UMR 7504, F-67034 Strasbourg, France.
  • Gilliot P; CNRS, IPCMS, UMR 7504, F-67034 Strasbourg, France.
  • Mely Y; Université de Strasbourg, Laboratoire de Biophotonique et Pharmacologie, UMR 7213 CNRS, Faculté de Pharmacie, 74, Route du Rhin, F-67401 ILLKIRCH, France.
  • Klymchenko AS; Université de Strasbourg, Laboratoire de Biophotonique et Pharmacologie, UMR 7213 CNRS, Faculté de Pharmacie, 74, Route du Rhin, F-67401 ILLKIRCH, France.
Nat Photonics ; 11(10): 657-663, 2017 Oct.
Article en En | MEDLINE | ID: mdl-28983324
ABSTRACT
Here, we explore the enhancement of single molecule emission by polymeric nano-antenna that can harvest energy from thousands of donor dyes to a single acceptor. In this nano-antenna, the cationic dyes are brought together in very close proximity using bulky counterions, thus enabling ultrafast diffusion of excitation energy (≤30 fs) with minimal losses. Our 60-nm nanoparticles containing >10,000 rhodamine-based donor dyes can efficiently transfer energy to 1-2 acceptors resulting in an antenna effect of ~1,000. Therefore, single Cy5-based acceptors become 25-fold brighter than quantum dots QD655. This unprecedented amplification of the acceptor dye emission enables observation of single molecules at illumination powers (1-10 mW cm-2) that are >10,000-fold lower than typically required in single-molecule measurements. Finally, using a basic setup, which includes a 20X air objective and a sCMOS camera, we could detect single Cy5 molecules by simply shining divergent light on the sample at powers equivalent to sunlight.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Nat Photonics Año: 2017 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Nat Photonics Año: 2017 Tipo del documento: Article País de afiliación: Francia