Your browser doesn't support javascript.
loading
Factors affecting eye drop instillation in glaucoma patients with visual field defect.
Naito, Tomoko; Namiguchi, Koji; Yoshikawa, Keiji; Miyamoto, Kazuhisa; Mizoue, Shiro; Kawashima, Yoichi; Shiraishi, Atushi; Shiraga, Fumio.
Afiliación
  • Naito T; Department of Ophthalmology, Okayama University Graduate School of Medicine, Okayama, Japan.
  • Namiguchi K; Department of Ophthalmology, Ehime University Graduate School of Medicine, Ehime, Japan.
  • Yoshikawa K; Yoshikawa Eye Clinic, Tokyo, Japan.
  • Miyamoto K; Sumitomo Besshi Hospital, Ehime, Japan.
  • Mizoue S; Department of Ophthalmology, Ehime University Graduate School of Medicine, Ehime, Japan.
  • Kawashima Y; Kyoto Hitomi Care Research, Kyoto, Japan.
  • Shiraishi A; Department of Ophthalmology, Ehime University Graduate School of Medicine, Ehime, Japan.
  • Shiraga F; Department of Ophthalmology, Okayama University Graduate School of Medicine, Okayama, Japan.
PLoS One ; 12(10): e0185874, 2017.
Article en En | MEDLINE | ID: mdl-29023521
ABSTRACT

BACKGROUND:

To investigate the success rate of eye drop instillation in glaucoma patients with visual field defect as well as non-glaucoma volunteers. Factors that may affect the success rate of eye drop instillation were also evaluated.

DESIGN:

A prospective, observational study.

PARTICIPANTS:

Seventy-eight glaucoma patients and 85 non-glaucoma volunteers were recruited in this study.

METHODS:

Open angle glaucoma patients with visual field defect as well as non-glaucoma volunteers were asked to video record their procedures of eye drop instillation using a 5-mL plastic bottle of artificial tear solution. Success of eye drop instillation was judged on video based on the first one drop of solution successfully applied on the cornea, by two investigators. MAIN OUTCOME

MEASURES:

Success rate of eye drop instillation in glaucoma patients and non-glaucoma volunteers. Factors related to success rate of eye drop instillation, such as visual field defect and clinical characteristics, were also analyzed using multivariable logistic regression.

RESULTS:

No significant deference in mean age was observed between two groups (glaucoma 64.5 ± 14.4 years, non-glaucoma 60.9 ± 14.1 years, P = 0.1156). Success rate of eye drop instillation was significantly lower (P = 0.0215) in glaucoma patients (30/78; 38.5%) than in non-glaucoma volunteers (48/85; 56.5%). The most frequent reason of instillation failure in glaucoma patients was touching the bulbar conjunctiva, cornea, eyelid or eyelashes with the tip of the bottle (29.5%). Multivariable logistic regression analysis identified lower corrected visual acuity (VA) (≤ 1.0; odds ratio [OR] = 0.20, 95% confidence interval [CI] 0.04-0.93, P = 0.0411), lower mean deviation (MD) (< -12 dB; OR = 0.20, 95% CI 0.05-0.86, P = 0.0307) and visual field defect (VFD) in the inferior hemifield (OR = 0.11, 95% CI 0.02-0.34, P < 0.001) to be significantly related to instillation failure in glaucoma patients.

CONCLUSIONS:

Success rate of eye drop instillation was significantly lower in glaucoma patients than in non-glaucoma volunteers. Corrected VA ≤ 1.0, MD < -12 dB and/or VFD in the inferior hemifield may be related to failure of eye drop instillation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Soluciones Oftálmicas / Trastornos de la Visión / Glaucoma de Ángulo Abierto Tipo de estudio: Clinical_trials / Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Soluciones Oftálmicas / Trastornos de la Visión / Glaucoma de Ángulo Abierto Tipo de estudio: Clinical_trials / Observational_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Japón
...