Hydrogen-peroxide and silicone-hydrogel contact lenses: Worsening of external eye condition and tear film instability.
Moro, A; Fagnola, M; Picarazzi, S; Di Dio, A; Pastori, V; Lecchi, M; Tavazzi, S.
Afiliación
  • Moro A; Materials Science Department, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy.
  • Fagnola M; COMiB, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy.
  • Picarazzi S; Materials Science Department, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy.
  • Di Dio A; Materials Science Department, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy.
  • Pastori V; University of Milano Bicocca, Department of Biotechnology and Bioscience, Piazza della Scienza 2, I-20126 Milan, Italy; COMiB, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy.
  • Lecchi M; University of Milano Bicocca, Department of Biotechnology and Bioscience, Piazza della Scienza 2, I-20126 Milan, Italy; COMiB, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy.
  • Tavazzi S; Materials Science Department, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy; COMiB, University of Milano Bicocca, Via Cozzi 55, I-20125 Milan, Italy. Electronic address: silvia.tavazzi@unimib.it.
Cont Lens Anterior Eye ; 41(2): 157-161, 2018 04.
Article en En | MEDLINE | ID: mdl-29066042
PURPOSE: The aim is discussing the origins of worsening of external eye condition (EEC) and of tear film (TF) instability after wear of silicone-hydrogel contact lenses (CLs) with hydrogen-peroxide (H2O2) care system. METHODS: EEC and TF stability were evaluated before and after 15days of wear combined with different care systems: (1) H2O2, (2) detergent solution and H2O2, (3) multipurpose solution (MPS), (4) H2O2 and artificial tears. In-vitro cell mortality tests were performed after 24h cell incubation with CLs treated with H2O2. Photon correlation spectroscopy (PCS) was carried out on tears of non-wearers and CL wearers who used MPS or H2O2 solution. RESULTS: Worsening of EEC was observed only for the group using H2O2 (group 1). In-vitro, cell mortality was found higher for worn CL than for unworn CLs. Worsening of TF stability was observed regardless of care system and also PCS results on tears of CL wearers were found different compared to non-wearers regardless of care system. The only observed remedy for tear instability of CL wearers was found to be the administration of artificial tears. CONCLUSIONS: Worsening of EEC of CL wearers using H2O2 is attributed to H2O2 scarce cleaning efficacy, which can be solved by adding a CL detergent solution. The origin of TF instability is found to be different. A remedy was found to be the administration of artificial tears, whose effect could be attributed either to the role of specific components or to rinsing and replacement of TF during wear.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polietilenglicoles / Siliconas / Lágrimas / Soluciones para Lentes de Contacto / Enfermedades de la Conjuntiva / Lentes de Contacto Hidrofílicos / Enfermedades de la Córnea / Enfermedades de los Párpados / Peróxido de Hidrógeno Límite: Humans Idioma: En Revista: Cont Lens Anterior Eye Año: 2018 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polietilenglicoles / Siliconas / Lágrimas / Soluciones para Lentes de Contacto / Enfermedades de la Conjuntiva / Lentes de Contacto Hidrofílicos / Enfermedades de la Córnea / Enfermedades de los Párpados / Peróxido de Hidrógeno Límite: Humans Idioma: En Revista: Cont Lens Anterior Eye Año: 2018 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Reino Unido