Your browser doesn't support javascript.
loading
Verification of junction dose between VMAT arcs of total body irradiation using a Sun Nuclear ArcCHECK phantom.
Morrison, Colm T; Symons, Kirsty L; Woodings, Simon J; House, Michael J.
Afiliación
  • Morrison CT; Department of Radiation Oncology, Genesis Cancer Care WA, Fiona Stanley Hospital, 11 Robin Warren Drive, Murdoch, 6150, Western Australia.
  • Symons KL; School of Physics, The University of Western Australia, 35 Stirling Highway, Crawley, 6009, Western Australia.
  • Woodings SJ; Department of Radiation Oncology, Genesis Cancer Care WA, Fiona Stanley Hospital, 11 Robin Warren Drive, Murdoch, 6150, Western Australia.
  • House MJ; Department of Radiation Oncology, Genesis Cancer Care WA, Fiona Stanley Hospital, 11 Robin Warren Drive, Murdoch, 6150, Western Australia.
J Appl Clin Med Phys ; 18(6): 177-182, 2017 Nov.
Article en En | MEDLINE | ID: mdl-29082594
ABSTRACT
A volumetric modulated arc therapy (VMAT) approach to total body irradiation (TBI) has recently been introduced at our institution. The planning target volume (PTV) is divided into separate sub-volumes, each being treated with 2 arcs with their own isocentre. Pre-treatment quality assurance of beams is performed on a Sun Nuclear ArcCHECK diode array. Measurement of junction regions between VMAT arcs with separate isocentres has previously been performed with point dose ionization chamber measurements, or with films. Translations of the ArcCHECK with respect to a known distance between the adjacent isocentres of two arcs, which are repeated with the ArcCHECK in an inverted position, allows the recording of a junction dose map. A 3%/3 mm global gamma analysis (10% threshold) pass rate for arc junctions were comparable to their component arcs. Dose maps of junction regions between adjacent arcs with different isocentres can be readily measured on a Sun Nuclear ArcCHECK diode array.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiometría / Planificación de la Radioterapia Asistida por Computador / Irradiación Corporal Total / Fantasmas de Imagen / Radioterapia de Intensidad Modulada Límite: Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiometría / Planificación de la Radioterapia Asistida por Computador / Irradiación Corporal Total / Fantasmas de Imagen / Radioterapia de Intensidad Modulada Límite: Humans Idioma: En Revista: J Appl Clin Med Phys Asunto de la revista: BIOFISICA Año: 2017 Tipo del documento: Article