Your browser doesn't support javascript.
loading
Application of ultrasound imaging biomarkers (HistoScanning™) improves staging reliability of prostate biopsies.
Hamann, M F; Meyer, D; Knüpfer, S; Fuchs, J; Jünemann, K P; Naumann, C M.
Afiliación
  • Hamann MF; Department of Urology and Pediatric Urology, University Hospital Schleswig-Holstein, UKSH, Campus Kiel, Arnold Heller Strasse 3, 24105, Kiel, Germany. moritzhamann@icloud.com.
  • Meyer D; Department of Urology and Pediatric Urology, University Hospital Schleswig-Holstein, UKSH, Campus Kiel, Arnold Heller Strasse 3, 24105, Kiel, Germany.
  • Knüpfer S; Department of Urology and Pediatric Urology, University Hospital Schleswig-Holstein, UKSH, Campus Kiel, Arnold Heller Strasse 3, 24105, Kiel, Germany.
  • Fuchs J; Department of Urology and Pediatric Urology, University Hospital Schleswig-Holstein, UKSH, Campus Kiel, Arnold Heller Strasse 3, 24105, Kiel, Germany.
  • Jünemann KP; Department of Urology and Pediatric Urology, University Hospital Schleswig-Holstein, UKSH, Campus Kiel, Arnold Heller Strasse 3, 24105, Kiel, Germany.
  • Naumann CM; Department of Urology and Pediatric Urology, University Hospital Schleswig-Holstein, UKSH, Campus Kiel, Arnold Heller Strasse 3, 24105, Kiel, Germany.
BMC Res Notes ; 10(1): 579, 2017 Nov 09.
Article en En | MEDLINE | ID: mdl-29121982
ABSTRACT

OBJECTIVE:

Imaging biomarkers like HistoScanning™ augment the informative value of ultrasound. Analogue image-guidance might improve the diagnostic accuracy of prostate biopsies and reduce misclassifications in preoperative staging and grading.

RESULTS:

Comparison of 77 image-guided versus 88 systematic prostate biopsies revealed that incorrect staging and Gleason misclassification occurs less frequently in image-guided than in systematic prostate biopsies. Systematic prostate biopsies (4-36 cores, median 12 cores) tended to detect predominantly unilateral tumors (39% sensitivity, 90.9% specificity, 17.5% negative and 50% positive predictive values). Bilateral tumors were diagnosed more frequently by image-guided prostate biopsies (87.9% sensitivity, 72.7% specificity, 50% negative and 96.8% positive predictive values). Regarding the detection of lesions with high Gleason scores ≥ 3 + 4, systematic prostate and image-guided biopsies yielded sensitivity and specificity rates of 66.7% vs 93.5%, 86% vs 64.5%, as well as negative and positive predictive values of 71.2% vs 87%, and 83.3% vs 79.6%, respectively. Potential reason for systematic prostate biopsies missing the correct laterality and the correct Gleason score was a mismatch between the biopsy template and the respective pathological cancer localization. This supports the need for improved detection techniques such as ultrasound imaging biomarkers and image-adapted biopsies.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Ultrasonografía / Biopsia Guiada por Imagen / Estadificación de Neoplasias Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Humans / Male Idioma: En Revista: BMC Res Notes Año: 2017 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Ultrasonografía / Biopsia Guiada por Imagen / Estadificación de Neoplasias Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Humans / Male Idioma: En Revista: BMC Res Notes Año: 2017 Tipo del documento: Article País de afiliación: Alemania
...