Your browser doesn't support javascript.
loading
Diagnostic value of cone beam computed tomography (CBCT) in occult scaphoid and wrist fractures.
Borel, Christophe; Larbi, Ahmed; Delclaux, Stephanie; Lapegue, Franck; Chiavassa-Gandois, Helene; Sans, Nicolas; Faruch-Bilfeld, Marie.
Afiliación
  • Borel C; Service d'imagerie, CHU de Toulouse-Purpan, Bâtiment Pierre Paul Riquet, TSA 40031-31059 Toulouse, France. Electronic address: christophe.borel21@gmail.com.
  • Larbi A; Service d'imagerie médicale - CHU de Nîmes - 4 Rue du Professeur Robert Debré, 30029 Nîmes, France. Electronic address: larbi.ahmed@gmail.com.
  • Delclaux S; Service de chirurgie d'orthopédie et de traumatologie, CHU de Toulouse-Purpan, Bâtiment Pierre Paul Riquet, TSA 40031-31059 Toulouse, France. Electronic address: delclaux.s@chu-toulouse.fr.
  • Lapegue F; Service d'imagerie, CHU de Toulouse-Purpan, Bâtiment Pierre Paul Riquet, TSA 40031-31059 Toulouse, France. Electronic address: franck.lapegue@gmail.com.
  • Chiavassa-Gandois H; Service d'imagerie, CHU de Toulouse-Purpan, Bâtiment Pierre Paul Riquet, TSA 40031-31059 Toulouse, France. Electronic address: chiavassa.h@chu-toulouse.fr.
  • Sans N; Service d'imagerie, CHU de Toulouse-Purpan, Bâtiment Pierre Paul Riquet, TSA 40031-31059 Toulouse, France. Electronic address: sans.n@chu-toulouse.fr.
  • Faruch-Bilfeld M; Service d'imagerie, CHU de Toulouse-Purpan, Bâtiment Pierre Paul Riquet, TSA 40031-31059 Toulouse, France. Electronic address: faruch.m@chu-toulouse.fr.
Eur J Radiol ; 97: 59-64, 2017 Dec.
Article en En | MEDLINE | ID: mdl-29153368
ABSTRACT

OBJECTIVE:

Evaluate the diagnostic value of cone beam computed tomography (CBCT) for scaphoid and wrist fractures that are missed on standard radiographs. MATERIALS AND

METHODS:

Between September 2014 and October 2015, we prospectively enrolled 49 patients with a clinically suspected scaphoid fracture following an acute injury but had normal radiographs. Each patients underwent radiographs, CBCT and (magnetic resonance imaging) MRI within 7days of the initial injury event. Both exam were evaluated independently by two radiologists.

RESULTS:

For scaphoid cortical fractures CBCT sensitivity is 100% (95% CI 75%-100%), specificity 97% (95% CI 83%-100%). CBCT diagnosed all 24 corticals wrist fractures, corresponding to a sensitivity of 100% (95% CI 83%-100%), specificity of 95% (95% CI 75%-100%). Kappa agreement rate between the two radiologists was K=0.95 (95% CI 0.85-1) for scaphoid fractures and K=0.87 (95% CI 0.73-1) for wrist fractures.

CONCLUSIONS:

CBCT is superior to radiographs for diagnosing occult cortical fractures. Because of its low radiation dose, we believe that CBCT can be used in current practice as a replacement or supplement to radiographs to detect these fractures and optimize the cost-effectiveness ratio by limiting the number of needless immobilizations.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos de la Muñeca / Hueso Escafoides / Fracturas Óseas Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos de la Muñeca / Hueso Escafoides / Fracturas Óseas Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Año: 2017 Tipo del documento: Article