Your browser doesn't support javascript.
loading
Validity of low-resolution eye-tracking to assess eye movements during a rapid number naming task: performance of the eyetribe eye tracker.
Raynowska, Jenelle; Rizzo, John-Ross; Rucker, Janet C; Dai, Weiwei; Birkemeier, Joel; Hershowitz, Julian; Selesnick, Ivan; Balcer, Laura J; Galetta, Steven L; Hudson, Todd.
Afiliación
  • Raynowska J; a Department of Neurology , NYU School of Medicine , New York , NY , USA.
  • Rizzo JR; a Department of Neurology , NYU School of Medicine , New York , NY , USA.
  • Rucker JC; c Department of Physical Medicine & Rehabilitation , NYU School of Medicine , New York , NY , USA.
  • Dai W; a Department of Neurology , NYU School of Medicine , New York , NY , USA.
  • Birkemeier J; a Department of Neurology , NYU School of Medicine , New York , NY , USA.
  • Hershowitz J; b Department of Electrical & Computer Engineering , NYU Tandon School of Engineering , New York , NY , USA.
  • Selesnick I; c Department of Physical Medicine & Rehabilitation , NYU School of Medicine , New York , NY , USA.
  • Balcer LJ; c Department of Physical Medicine & Rehabilitation , NYU School of Medicine , New York , NY , USA.
  • Galetta SL; b Department of Electrical & Computer Engineering , NYU Tandon School of Engineering , New York , NY , USA.
  • Hudson T; a Department of Neurology , NYU School of Medicine , New York , NY , USA.
Brain Inj ; 32(2): 200-208, 2018.
Article en En | MEDLINE | ID: mdl-29211506
OBJECTIVE: To evaluate the performance of the EyeTribe compared to the EyeLink for eye movement recordings during a rapid number naming test in healthy control participants. BACKGROUND: With the increasing accessibility of portable, economical, video-based eye trackers such as the EyeTribe, there is growing interest in these devices for eye movement recordings, particularly in the domain of sports-related concussion. However, prior to implementation there is a primary need to establish the validity of these devices. One current limitation of portable eye trackers is their sampling rate (30-60 samples per second, or Hz), which is typically well below the benchmarks achieved by their research-grade counterparts (e.g., the EyeLink, which samples at 500-2000 Hz). METHODS: We compared video-oculographic measurements made using the EyeTribe with those of the EyeLink during a digitized rapid number naming task (the King-Devick test) in a convenience sample of 30 controls. RESULTS: EyeTribe had loss of signal during recording, and failed to reproduce the typical shape of saccadic main sequence relationships. In addition, EyeTribe data yielded significantly fewer detectable saccades and displayed greater variance of inter-saccadic intervals than the EyeLink system. CONCLUSION: Caution is advised prior to implementation of low-resolution eye trackers for objective saccade assessment and sideline concussion screening.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Movimientos Oculares / Medidas del Movimiento Ocular Tipo de estudio: Clinical_trials / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Brain Inj Asunto de la revista: CEREBRO Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Movimientos Oculares / Medidas del Movimiento Ocular Tipo de estudio: Clinical_trials / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Brain Inj Asunto de la revista: CEREBRO Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido