Complications of Semiconstrained Distal Radioulnar Joint Arthroplasty.
Bellevue, Kate D; Thayer, Mary K; Pouliot, Michael; Huang, Jerry I; Hanel, Douglas P.
Afiliación
  • Bellevue KD; Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA.
  • Thayer MK; Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA.
  • Pouliot M; Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA.
  • Huang JI; Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA.
  • Hanel DP; Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA. Electronic address: dhanel@uw.edu.
J Hand Surg Am ; 43(6): 566.e1-566.e9, 2018 06.
Article en En | MEDLINE | ID: mdl-29275901
ABSTRACT

PURPOSE:

The Aptis total distal radioulnar joint (DRUJ) prosthesis is a semiconstrained implant designed for treatment of DRUJ arthritis and instability. The purpose of this study was to analyze short-term complications of this device.

METHODS:

We performed a retrospective chart review of patients undergoing semiconstrained DRUJ arthroplasty from 2007 to 2015 at a single institution. Records were analyzed for complications and the need for subsequent surgical procedures.

RESULTS:

Two senior hand surgeons at one institution performed 52 semiconstrained DRUJ arthroplasties over 8 years. Nineteen complications necessitating operative management occurred in 15 patients (29%). A total of 26 procedures were undertaken to address these complications. Complications included 4 periprosthetic fractures, 3 infections, 2 instances of aseptic loosening, 2 implant component failures, 1 instance of screw loosening, 3 neuromas requiring neurectomy, 2 instances of finger stiffness necessitating extensor tenolysis, and 2 cases of heterotopic ossification at the DRUJ. Three of the 52 implants were revised (6%) and 2 were explanted (4%); 3 of these (6%) were caused by deep infection.

CONCLUSIONS:

There is limited literature on outcomes of the semiconstrained DRUJ prosthesis. Prior studies reported low complication rates, with 0% to 5% revisions. In the current clinical series, 29% of patients required further surgery for complications, the most common reasons for which were periprosthetic fracture and infection. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artritis / Articulación de la Muñeca / Artroplastia de Reemplazo / Inestabilidad de la Articulación / Prótesis Articulares Tipo de estudio: Observational_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Hand Surg Am Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artritis / Articulación de la Muñeca / Artroplastia de Reemplazo / Inestabilidad de la Articulación / Prótesis Articulares Tipo de estudio: Observational_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Hand Surg Am Año: 2018 Tipo del documento: Article