Your browser doesn't support javascript.
loading
Impact of tissue kinetic heterogeneity on PET quantification: case study with the L-[1-11C]leucine PET method for cerebral protein synthesis rates.
Veronese, Mattia; Bertoldo, Alessandra; Tomasi, Giampaolo; Smith, Carolyn Beebe; Schmidt, Kathleen C.
Afiliación
  • Veronese M; Section on Neuroadaptation & Protein Metabolism, National Institute of Mental Health, Bethesda, Maryland, USA.
  • Bertoldo A; Department of Neuroimaging, IoPPN, King's college London, London, UK.
  • Tomasi G; Department of Information Engineering, University of Padova, Padova, Italy.
  • Smith CB; Padua Neuroscience Center, University of Padova, Padova, Italy.
  • Schmidt KC; Section on Neuroadaptation & Protein Metabolism, National Institute of Mental Health, Bethesda, Maryland, USA.
Sci Rep ; 8(1): 931, 2018 01 17.
Article en En | MEDLINE | ID: mdl-29343731
ABSTRACT
Functional quantification with PET is generally based on modeling that assumes tissue regions are kinetically homogeneous. Even in regions sufficiently small to approach homogeneity, spillover due to resolution limitations of PET scanners may introduce heterogeneous kinetics into measured data. Herein we consider effects of kinetic heterogeneity at the smallest volume accessible, the single image voxel. We used L-[1-11C]leucine PET and compared rates of cerebral protein synthesis (rCPS) estimated voxelwise with methods that do (Spectral Analysis Iterative Filter, SAIF) and do not (Basis Function Method, BFM) allow for kinetic heterogeneity. In high resolution PET data with good counting statistics BFM produced estimates of rCPS comparable to SAIF, but at lower computational cost; thus the simpler, less costly method can be applied. With poorer counting statistics (lower injected radiotracer doses), BFM estimates were more biased. In data smoothed to simulate lower resolution PET, BFM produced estimates of rCPS 9-14% higher than SAIF, overestimation consistent with applying a homogeneous tissue model to kinetically heterogeneous data. Hence with lower resolution data it is necessary to account for kinetic heterogeneity in the analysis. Kinetic heterogeneity may impact analyses of other tracers and scanning protocols differently; assessments should be made on a case by case basis.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Biosíntesis de Proteínas / Encéfalo / Radioisótopos de Carbono / Leucina Límite: Humans Idioma: En Revista: Sci Rep Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Biosíntesis de Proteínas / Encéfalo / Radioisótopos de Carbono / Leucina Límite: Humans Idioma: En Revista: Sci Rep Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos