Your browser doesn't support javascript.
loading
Micro-Capillary Coatings Based on Spiropyran Polymeric Brushes for Metal Ion Binding, Detection, and Release in Continuous Flow.
Dunne, Aishling; Delaney, Colm; McKeon, Aoife; Nesterenko, Pavel; Paull, Brett; Benito-Lopez, Fernando; Diamond, Dermot; Florea, Larisa.
Afiliación
  • Dunne A; Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland. aishling.dunne58@mail.dcu.ie.
  • Delaney C; Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland. colm.delaney@dcu.ie.
  • McKeon A; Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland. aoifemckeon@rcsi.ie.
  • Nesterenko P; Australian Centre for Research on Separation Science, and ARC Centre of Excellence for Electromaterials Science, Hobart, Tasmania 7001, Australia. pavel.nesterenko@utas.edu.au.
  • Paull B; Australian Centre for Research on Separation Science, and ARC Centre of Excellence for Electromaterials Science, Hobart, Tasmania 7001, Australia. brett.paull@utas.edu.au.
  • Benito-Lopez F; Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Microfluidics Cluster UPV/EHU, Analytical Chemistry Department, University of the Basque Country UPV/EHU, Vitoria-Gasteiz 01006, Spain. fernando.benito@ehu.eus.
  • Diamond D; Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland. dermot.diamond@dcu.ie.
  • Florea L; Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland. larisa.florea@dcu.ie.
Sensors (Basel) ; 18(4)2018 Apr 04.
Article en En | MEDLINE | ID: mdl-29617290
ABSTRACT
Micro-capillaries, capable of light-regulated binding and qualitative detection of divalent metal ions in continuous flow, have been realised through functionalisation with spiropyran photochromic brush-type coatings. Upon irradiation with UV light, the coating switches from the passive non-binding spiropyran form to the active merocyanine form, which binds different divalent metal ions (Zn2+, Co2+, Cu2+, Ni2+, Cd2+), as they pass through the micro-capillary. Furthermore, the merocyanine visible absorbance spectrum changes upon metal ion binding, enabling the ion uptake to be detected optically. Irradiation with white light causes reversion of the merocyanine to the passive spiropyran form, with simultaneous release of the bound metal ion from the micro-capillary coating.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Qualitative_research Idioma: En Revista: Sensors (Basel) Año: 2018 Tipo del documento: Article País de afiliación: Irlanda

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Qualitative_research Idioma: En Revista: Sensors (Basel) Año: 2018 Tipo del documento: Article País de afiliación: Irlanda