Your browser doesn't support javascript.
loading
Evaluation of the placement and maintenance of central venous jugular catheters in critically ill dogs and cats.
Reminga, Christin L; Silverstein, Deborah C; Drobatz, Kenneth J; Clarke, Dana L.
Afiliación
  • Reminga CL; Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA.
  • Silverstein DC; Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA.
  • Drobatz KJ; Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA.
  • Clarke DL; Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA.
J Vet Emerg Crit Care (San Antonio) ; 28(3): 232-243, 2018 May.
Article en En | MEDLINE | ID: mdl-29687942
OBJECTIVE: To describe problems noted during central venous jugular catheter (CVJC) placement, conditions associated with unsuccessful catheterization, and CVJC maintenance complications. DESIGN: Prospective observational study from September 2014 to September 2015. SETTING: University veterinary teaching hospital. ANIMALS: Twenty-seven dogs and 20 cats hospitalized in a veterinary ICU. Patients were excluded if previously hospitalized with a CVJC or lacked sufficient data. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Ninety-one percent of indwelling CVJCs were placed successfully (43/47, 95% CI: 80%, 98%). Procedural-related difficulties that resulted in the inability to place a CVJC totaled 18/63 (28.6%, 95% CI: 18%, 41%) and included the inability to puncture the vessel (10), hematoma (6), malposition (1), and dislodgement (1). Procedural complications occurred in 24/47 patients (51%, 95% CI: 36%, 66%) and included cardiac dysrhythmias (13), hematoma (6), CVJC placement failure (4), and malposition (1). Risk factors associated with multiple catheterization attempts included increased age (7.5 years [± 4.2] vs 10.6 years [± 4.1], P = 0.04), smaller size (8.0 kg [0.6-51.9 kg] vs 4.4 kg [2.6-6.8 kg], P < 0.01) and thinner body condition score (median 5/9 [2/9-9/9] vs 4/9 [2/9-7/9], P = 0.04). The risk factor associated with dysrhythmias was smaller patient size (6.8 kg [2.6-51.9 kg] vs 4.8 kg [0.6-29.5 kg], P = 0.04). Eighteen indwelling complications occurred in 14 patients and included mechanical obstruction (7), skin irritation (6), malposition (4), and inflammation (1). Risk factors for indwelling complications included longer dwell time (5 days [2-30] vs 3 days [1-10], P < 0.01) and the administration of an irritant medication (P = 0.02). CONCLUSIONS: Complications were documented in the placement and maintenance of CVJCs in critically ill patients with a low incidence of life-threatening sequelae. Risk factors associated with both unsuccessful CVJC placement and indwelling CVJC complications were identified.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cateterismo Venoso Central / Enfermedades de los Gatos / Enfermedades de los Perros Tipo de estudio: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Animals País/Región como asunto: America do norte Idioma: En Revista: J Vet Emerg Crit Care (San Antonio) Asunto de la revista: MEDICINA DE EMERGENCIA / MEDICINA VETERINARIA / TERAPIA INTENSIVA Año: 2018 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cateterismo Venoso Central / Enfermedades de los Gatos / Enfermedades de los Perros Tipo de estudio: Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Animals País/Región como asunto: America do norte Idioma: En Revista: J Vet Emerg Crit Care (San Antonio) Asunto de la revista: MEDICINA DE EMERGENCIA / MEDICINA VETERINARIA / TERAPIA INTENSIVA Año: 2018 Tipo del documento: Article Pais de publicación: Estados Unidos