Your browser doesn't support javascript.
loading
Malleostapedotomy with the self-fixing and articulated titanium piston.
Burggraaf, J; Mylanus, E A M; Pennings, R J E; Cremers, Cor.
Afiliación
  • Burggraaf J; Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
  • Mylanus EAM; Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
  • Pennings RJE; Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
  • Cremers C; Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands. cor.cremers@radboudumc.nl.
Eur Arch Otorhinolaryngol ; 275(7): 1715-1722, 2018 Jul.
Article en En | MEDLINE | ID: mdl-29779038
OBJECTIVE: To analyze the results of malleostapedotomy performed by applying the self-fixing and articulated titanium piston according to Häusler. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: This study concerns a retrospective analysis of the results of malleostapedotomy with the use of a self-fixing articulated titanium piston in 16 ears of 16 consecutively treated patients between 2005 and 2009. The medical files were used for the acquisition of data on medical and surgical history and to obtain pre- and postoperative audiometry. Diagnosis and outcomes of mainly revision surgeries are presented and compared to the literature. MAIN OUTCOME MEASURES: Effect of (revision) malleostapedotomy by evaluating postoperative audiometry and air-bone gap closure. RESULTS: The postoperative air-bone gap closure was ≤ 10 dB in 9/16 (56%) ears and within ≤ 20 dB in 13/16 (81%) ears. The mean postoperative air-bone gap was 14.3 dB HL (0.5-2.0 kHz) and 17.3 dB HL (0.5-4.0 kHz). Postoperatively, there was no increase in bone conduction thresholds larger than 3 dB (0.5-2.0 kHz) and postoperative dizziness was absent or very limited and transient. CONCLUSIONS: The malleostapedotomy procedure has become surgically less demanding over time by the technical improvements present in the nowadays available pistons. The design of the self-fixing and articulated titanium piston used in the present group of patients allows a safe and straight-forward malleostapedotomy procedure. Present hearing outcomes match with results presented in the literature.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis e Implantes / Cirugía del Estribo / Titanio / Pérdida Auditiva / Martillo Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Arch Otorhinolaryngol Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis e Implantes / Cirugía del Estribo / Titanio / Pérdida Auditiva / Martillo Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Arch Otorhinolaryngol Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Alemania