Your browser doesn't support javascript.
loading
Tracking Infiltration Front Depth Using Time-lapse Multi-offset Gathers Collected with Array Antenna Ground Penetrating Radar.
Saito, Hirotaka; Kuroda, Seiichiro; Iwasaki, Toshiki; Fujimaki, Haruyuki; Nagai, Nobuhito; Sala, Jacopo.
Afiliación
  • Saito H; Graduate School of Agriculture, Tokyo University of Agriculture and Technology; hiros@cc.tuat.ac.jp.
  • Kuroda S; National Institute for Rural Engineering, National Agriculture and Food Research Organization.
  • Iwasaki T; Graduate School of Agriculture, Tokyo University of Agriculture and Technology.
  • Fujimaki H; Arid Land Research Center, Tottori University.
  • Nagai N; GeoFive Co. Ltd.
  • Sala J; 3D-Radar.
J Vis Exp ; (135)2018 05 01.
Article en En | MEDLINE | ID: mdl-29782019
ABSTRACT
A Ground Penetrating Radar (GPR) system based on a ground-coupled, densely populated antenna array was used to collect data during an infiltration experiment conducted at a test site near the Tottori Sand Dune, Japan. The antenna array used in this study consists of 10 transmitting antennas (Tx) and 11 receiving antennas (Rx). For this experiment, the system was configured to use all possible Tx-Rx pairings, resulting in a Multi-Offset Gather (MOG) consisting of 110 Tx-Rx combinations. The array was left stationary at a position directly above the infiltration area and data were collected every 1.5 seconds using a time-based trigger. Common-Offset Gather (COG) and Common Mid-Point (CMP) data cubes were reconstructed from the MOG data during post-processing. There have been few studies that used time-lapse CMP data to estimate changes in velocity of propagation. In this study, electromagnetic (EM) wave velocity was estimated heuristically at 1-minute intervals from the reconstructed CMP data through curve fitting, using the hyperbola equation. We then proceeded to calculate the depth of the wetting front. The evolution of the wetting front over time obtain through this method is consistent with the observations from a soil moisture sensor which was placed at a depth below 20 cm. The results obtained in this study demonstrate the ability of such array GPR system to monitor a subsurface dynamic process like water infiltration accurately and quantitatively.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radar / Monitoreo del Ambiente Idioma: En Revista: J Vis Exp Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radar / Monitoreo del Ambiente Idioma: En Revista: J Vis Exp Año: 2018 Tipo del documento: Article