Your browser doesn't support javascript.
loading
Sample-to-answer palm-sized nucleic acid testing device towards low-cost malaria mass screening.
Choi, Gihoon; Prince, Theodore; Miao, Jun; Cui, Liwang; Guan, Weihua.
Afiliación
  • Choi G; Department of Electrical Engineering, Pennsylvania State University, University Park 16802, USA.
  • Prince T; Department of Electrical Engineering, Pennsylvania State University, University Park 16802, USA.
  • Miao J; Department of Entomology, Pennsylvania State University, University Park 16802, USA.
  • Cui L; Department of Entomology, Pennsylvania State University, University Park 16802, USA.
  • Guan W; Department of Electrical Engineering, Pennsylvania State University, University Park 16802, USA; Department of Biomedical Engineering, Pennsylvania State University, University Park 16802, USA. Electronic address: w.guan@psu.edu.
Biosens Bioelectron ; 115: 83-90, 2018 Sep 15.
Article en En | MEDLINE | ID: mdl-29803865
The effectiveness of malaria screening and treatment highly depends on the low-cost access to the highly sensitive and specific malaria test. We report a real-time fluorescence nucleic acid testing device for malaria field detection with automated and scalable sample preparation capability. The device consists a compact analyzer and a disposable microfluidic reagent compact disc. The parasite DNA sample preparation and subsequent real-time LAMP detection were seamlessly integrated on a single microfluidic compact disc, driven by energy efficient non-centrifuge based magnetic field interactions. Each disc contains four parallel testing units which could be configured either as four identical tests or as four species-specific tests. When configured as species-specific tests, it could identify two of the most life-threatening malaria species (P. falciparum and P. vivax). The NAT device is capable of processing four samples simultaneously within 50 min turnaround time. It achieves a detection limit of ~0.5 parasites/µl for whole blood, sufficient for detecting asymptomatic parasite carriers. The combination of the sensitivity, specificity, cost, and scalable sample preparation suggests the real-time fluorescence LAMP device could be particularly useful for malaria screening in the field settings.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Malaria Vivax / Malaria Falciparum / Técnicas de Diagnóstico Molecular Tipo de estudio: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Malaria Vivax / Malaria Falciparum / Técnicas de Diagnóstico Molecular Tipo de estudio: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies / Screening_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido