Your browser doesn't support javascript.
loading
Accurate Sequence Analysis of a Monoclonal Antibody by Top-Down and Middle-Down Orbitrap Mass Spectrometry Applying Multiple Ion Activation Techniques.
Fornelli, Luca; Srzentic, Kristina; Huguet, Romain; Mullen, Christopher; Sharma, Seema; Zabrouskov, Vlad; Fellers, Ryan T; Durbin, Kenneth R; Compton, Philip D; Kelleher, Neil L.
Afiliación
  • Fornelli L; Departments of Chemistry and Molecular Biosciences, and the Proteomics Center of Excellence , Northwestern University , 2145 North Sheridan Road , Evanston , Illinois 60208 , United States.
  • Srzentic K; Departments of Chemistry and Molecular Biosciences, and the Proteomics Center of Excellence , Northwestern University , 2145 North Sheridan Road , Evanston , Illinois 60208 , United States.
  • Huguet R; Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States.
  • Mullen C; Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States.
  • Sharma S; Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States.
  • Zabrouskov V; Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States.
  • Fellers RT; Departments of Chemistry and Molecular Biosciences, and the Proteomics Center of Excellence , Northwestern University , 2145 North Sheridan Road , Evanston , Illinois 60208 , United States.
  • Durbin KR; Proteinaceous, Incorporated , Evanston , Illinois 60201 , United States.
  • Compton PD; Departments of Chemistry and Molecular Biosciences, and the Proteomics Center of Excellence , Northwestern University , 2145 North Sheridan Road , Evanston , Illinois 60208 , United States.
  • Kelleher NL; Departments of Chemistry and Molecular Biosciences, and the Proteomics Center of Excellence , Northwestern University , 2145 North Sheridan Road , Evanston , Illinois 60208 , United States.
Anal Chem ; 90(14): 8421-8429, 2018 07 17.
Article en En | MEDLINE | ID: mdl-29894161
Targeted top-down (TD) and middle-down (MD) mass spectrometry (MS) offer reduced sample manipulation during protein analysis, limiting the risk of introducing artifactual modifications to better capture sequence information on the proteoforms present. This provides some advantages when characterizing biotherapeutic molecules such as monoclonal antibodies, particularly for the class of biosimilars. Here, we describe the results obtained analyzing a monoclonal IgG1, either in its ∼150 kDa intact form or after highly specific digestions yielding ∼25 and ∼50 kDa subunits, using an Orbitrap mass spectrometer on a liquid chromatography (LC) time scale with fragmentation from ion-photon, ion-ion, and ion-neutral interactions. Ultraviolet photodissociation (UVPD) used a new 213 nm solid-state laser. Alternatively, we applied high-capacity electron-transfer dissociation (ETD HD), alone or in combination with higher energy collisional dissociation (EThcD). Notably, we verify the degree of complementarity of these ion activation methods, with the combination of 213 nm UVPD and ETD HD producing a new record sequence coverage of ∼40% for TD MS experiments. The addition of EThcD for the >25 kDa products from MD strategies generated up to 90% of complete sequence information in six LC runs. Importantly, we determined an optimal signal-to-noise threshold for fragment ion deconvolution to suppress false positives yet maximize sequence coverage and implemented a systematic validation of this process using the new software TDValidator. This rigorous data analysis should elevate confidence for assignment of dense MS2 spectra and represents a purposeful step toward the application of TD and MD MS for deep sequencing of monoclonal antibodies.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Inmunoglobulina G / Análisis de Secuencia de Proteína / Rituximab / Antineoplásicos Inmunológicos Idioma: En Revista: Anal Chem Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Inmunoglobulina G / Análisis de Secuencia de Proteína / Rituximab / Antineoplásicos Inmunológicos Idioma: En Revista: Anal Chem Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos