Your browser doesn't support javascript.
loading
Ultrafast two-dimensional lithium beam emission spectroscopy diagnostic on the EAST tokamak.
Zoletnik, S; Hu, G H; Tál, B; Dunai, D; Anda, G; Asztalos, O; Pokol, G I; Kálvin, S; Németh, J; Krizsanóczi, T.
Afiliación
  • Zoletnik S; Wigner Research Centre for Physics, Budapest, Hungary.
  • Hu GH; Institute for Plasma Physics, Chinese Academy of Sciences, Hefei, China.
  • Tál B; Wigner Research Centre for Physics, Budapest, Hungary.
  • Dunai D; Wigner Research Centre for Physics, Budapest, Hungary.
  • Anda G; Wigner Research Centre for Physics, Budapest, Hungary.
  • Asztalos O; Budapest University of Technology and Economics, Budapest, Hungary.
  • Pokol GI; Budapest University of Technology and Economics, Budapest, Hungary.
  • Kálvin S; Wigner Research Centre for Physics, Budapest, Hungary.
  • Németh J; Wigner Research Centre for Physics, Budapest, Hungary.
  • Krizsanóczi T; Wigner Research Centre for Physics, Budapest, Hungary.
Rev Sci Instrum ; 89(6): 063503, 2018 Jun.
Article en En | MEDLINE | ID: mdl-29960560
ABSTRACT
A diagnostic instrument is described for the Experimental Advanced Superconducting Tokamak (EAST) for the measurement of the edge plasma electron density profile and plasma turbulence properties. An accelerated neutral lithium beam is injected into the tokamak and the Doppler shifted 670.8 nm light emission of the Li2p-2s transition is detected. A novel compact setup is used, where the beam injection and observation take place from the same equatorial diagnostic port and radial-poloidal resolution is achieved with microsecond time resolution. The observation direction is optimized in order to achieve a sufficient Doppler shift of the beam light to be able to separate from the strong edge lithium line emission on this lithium coated device. A 250 kHz beam chopping technique is also demonstrated for the removal of background light. First results show the capability of measuring turbulence and its poloidal flow velocity in the scrape-off layer and edge region and the resolution of details of transient phenomena like edge localized modes with few microsecond time resolution.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article País de afiliación: Hungria