Endobronchial Coils for Endoscopic Lung Volume Reduction: Best Practice Recommendations from an Expert Panel.
Slebos, Dirk-Jan; Ten Hacken, Nick H; Hetzel, Martin; Herth, Felix J F; Shah, Pallav L.
Afiliación
  • Slebos DJ; Department of Pulmonary Diseases, University of Groningen, University Medical Center Groningen (UMCG), Groningen, the Netherlands.
  • Ten Hacken NH; Groningen Research Institute for Asthma and COPD, University of Groningen, University Medical Center Groningen (UMCG), Groningen, the Netherlands.
  • Hetzel M; Department of Pulmonary Diseases, University of Groningen, University Medical Center Groningen (UMCG), Groningen, the Netherlands.
  • Herth FJF; Groningen Research Institute for Asthma and COPD, University of Groningen, University Medical Center Groningen (UMCG), Groningen, the Netherlands.
  • Shah PL; Krankenhaus vom Roten Kreuz, Stuttgart, Germany.
Respiration ; 96(1): 1-11, 2018.
Article en En | MEDLINE | ID: mdl-29991060
ABSTRACT
Endobronchial coils are an additional treatment option for lung volume reduction in patients with severe emphysema. Patient selection should be focused on patients with severe emphysema on optimal medical therapy and with evidence of severe hyperinflation. The technique is suitable in a broad range of patients with emphysema; however, patients with paraseptal emphysema, large focal (giant) bullae, significant co-morbidity and airway-predominant disease should be avoided. Treatment involves placing between 10 and 14 coils by bronchoscopy in the selected treatment lobe, with 2 lobes being treated sequentially. Lobe selection for treatment should be based on quantitative computed tomography, and the lobes with the greatest destruction should be targeted (excluding the right middle lobe). The treatment results in an improvement in pulmonary function, exercise performance and quality of life, particularly in patients with severe hyperinflation (residual volume > 200% predicted) and upper-lobe heterogeneous emphysema, but will also be of benefit in lower-lobe predominant and homogeneous emphysema. Finally, it has an acceptable safety profile, although special attention has to be paid to coil-associated opacity which is an inflammatory response that occurs in some patients treated with endobronchial coils.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neumonectomía / Enfisema Pulmonar / Pulmón Tipo de estudio: Guideline / Prognostic_studies Aspecto: Patient_preference Límite: Humans Idioma: En Revista: Respiration Año: 2018 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: CH / SUIZA / SUÍÇA / SWITZERLAND

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neumonectomía / Enfisema Pulmonar / Pulmón Tipo de estudio: Guideline / Prognostic_studies Aspecto: Patient_preference Límite: Humans Idioma: En Revista: Respiration Año: 2018 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: CH / SUIZA / SUÍÇA / SWITZERLAND