Your browser doesn't support javascript.
loading
Influence of Transmucosal Height on Loss of Prosthetic Abutment Torque After Mechanical Cycling.
da Silva, Karla Regina Nogueira; Joly, Júlio Cesar; Peruzzo, Daiane Cristina; Napimoga, Marcelo Henrique; Martinez, Elizabeth Ferreira.
Afiliación
  • da Silva KRN; 1 Department of Oral Implantology, São Leopoldo Mandic Institute and Research Center, Campinas, São Paulo, Brazil.
  • Joly JC; 1 Department of Oral Implantology, São Leopoldo Mandic Institute and Research Center, Campinas, São Paulo, Brazil.
  • Peruzzo DC; 1 Department of Oral Implantology, São Leopoldo Mandic Institute and Research Center, Campinas, São Paulo, Brazil.
  • Napimoga MH; 2 Department of Cell Biology, São Leopoldo Mandic Institute and Research Center, Campinas, São Paulo, Brazil.
  • Martinez EF; 2 Department of Cell Biology, São Leopoldo Mandic Institute and Research Center, Campinas, São Paulo, Brazil.
J Oral Implantol ; 44(6): 423-426, 2018 Dec.
Article en En | MEDLINE | ID: mdl-30011229
ABSTRACT
The aim of this study was to measure and record the universal transmucosal abutment height, and then evaluate whether it influenced loosening of the abutment screw by analyzing the torque and detorque values after mechanical cycling. Thirty-six implants, model CM Unitite, with internal conical connections (3.5 × 10 mm) and respective universal prosthetic abutments (n = 36, 3.25 × 6 mm), were divided into three groups (n = 12 each) with respective transmucosal heights of 0.8, 3.5, and 5.5 mm. Insertion torque of 20 Ncm was used in accordance with the manufacturer's specifications. Afterward, the samples were submitted to fatigue tests consisting of 500,000 cycles at a frequency of 2Hz, a dynamic compressive load of 120N, and an angle of 30°. The detorque values were measured with a digital torque meter and tabulated to perform statistical analyses; a level of significance of 5% was adopted. The mean detorque values (SD) obtained were 22.83 (6.30), 22.5 (5.45), and 19.41 (4.69) Ncm for transmucosal abutments with heights of 0.8, 3.5, and 5.5 mm, respectively, and showed no statistically significant difference ( P = .262). The authors of this study concluded that the transmucosal height of prosthetic abutments submitted to mechanical fatigue did not influence the detorque values.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Implantes Dentales / Pilares Dentales / Diseño de Implante Dental-Pilar Idioma: En Revista: J Oral Implantol Año: 2018 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Implantes Dentales / Pilares Dentales / Diseño de Implante Dental-Pilar Idioma: En Revista: J Oral Implantol Año: 2018 Tipo del documento: Article País de afiliación: Brasil