15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography.
Thomassen, Anders; Braad, Poul-Erik; Pedersen, Kasper T; Petersen, Henrik; Johansen, Allan; Diederichsen, Axel C P; Mickley, Hans; Jensen, Lisette O; Knuuti, Juhani; Gerke, Oke; Høilund-Carlsen, Poul F.
Afiliación
  • Thomassen A; Department of Nuclear Medicine, Odense University Hospital, Kløvervænget 47, 5000, Odense, Denmark. anders.thomassen@rsyd.dk.
  • Braad PE; Department of Nuclear Medicine, Odense University Hospital, Kløvervænget 47, 5000, Odense, Denmark.
  • Pedersen KT; Department of Nuclear Medicine, Odense University Hospital, Kløvervænget 47, 5000, Odense, Denmark.
  • Petersen H; Department of Nuclear Medicine, Odense University Hospital, Kløvervænget 47, 5000, Odense, Denmark.
  • Johansen A; Department of Nuclear Medicine, Odense University Hospital, Kløvervænget 47, 5000, Odense, Denmark.
  • Diederichsen ACP; Department of Cardiology, Odense University Hospital, Odense, Denmark.
  • Mickley H; Department of Cardiology, Odense University Hospital, Odense, Denmark.
  • Jensen LO; Department of Cardiology, Odense University Hospital, Odense, Denmark.
  • Knuuti J; Turku University Hospital and University of Turku, Turku, Finland.
  • Gerke O; Department of Nuclear Medicine, Odense University Hospital, Kløvervænget 47, 5000, Odense, Denmark.
  • Høilund-Carlsen PF; Department of Nuclear Medicine, Odense University Hospital, Kløvervænget 47, 5000, Odense, Denmark.
Int J Cardiovasc Imaging ; 34(12): 2011-2022, 2018 Dec.
Article en En | MEDLINE | ID: mdl-30066164
Combined myocardial flow reserve (MFR) by PET and CT coronary angiography (CTA) is a promising tool for assessment of coronary artery disease. Prior analyses of MFR/CTA has been performed as side-by-side interpretation, not as volume rendered, full hybrid analysis, with fused MFR/CTA. We aimed to: (i) establish a method for full hybrid analysis of MFR/CTA, (ii) validate the inter- and intra-observer reproducibility of MFR values, and (iii) determine the diagnostic value of side-by-side versus full hybrid MFR/CTA with 15-O-water PET. Forty-four outpatients scheduled for invasive coronary angiography (ICA) were enrolled prospectively. All underwent rest/stress 15-O-water PET/CTA with ICA as reference. Within two observers of different experience, the Pearson r at global and territorial level exceeded 0.953 for rest, stress, and MFR values, as determined by Carimas software. Within and between observers, the mean differences between rest, stress, and MFR values were close to zero and the confidence intervals for 95% limits of agreement were narrow. The diagnostic performance of full hybrid PET/CTA did not outperform the side-by-side approach, but performed better than MFR without CTA at vessel level: specificity 93% (95% confidence limits: 89-97%) versus 76% (64-88%), p = 0.0004; positive predictive value 71% (55-86%) versus 51% (37-65%), p = 0.0001; accuracy 90% (84-95%) versus 77% (69-84%), p = 0.0009. MFR showed high reproducibility within and between observers of different experience. The full hybrid model was not superior to side-by-side interpretation of MFR/CTA, but proved better than MFR alone at vessel level with regard to specificity, positive predictive value, and accuracy.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radioisótopos de Oxígeno / Enfermedad de la Arteria Coronaria / Angiografía Coronaria / Vasos Coronarios / Imagen de Perfusión Miocárdica / Tomografía Computarizada Multidetector / Tomografía Computarizada por Tomografía de Emisión de Positrones / Angiografía por Tomografía Computarizada Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article País de afiliación: Dinamarca Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radioisótopos de Oxígeno / Enfermedad de la Arteria Coronaria / Angiografía Coronaria / Vasos Coronarios / Imagen de Perfusión Miocárdica / Tomografía Computarizada Multidetector / Tomografía Computarizada por Tomografía de Emisión de Positrones / Angiografía por Tomografía Computarizada Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Cardiovasc Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article País de afiliación: Dinamarca Pais de publicación: Estados Unidos