Your browser doesn't support javascript.
loading
Evasion maneuver for transseptal approach during cryoballoon pulmonary vein isolation.
Blockhaus, Christian; Waibler, Hans-Peter; Gülker, Jan-Erik; Klues, Heinrich; Bufe, Alexander; Shin, Dong-In.
Afiliación
  • Blockhaus C; Department of Cardiology, Heart Centre Niederrhein, Helios Clinics Krefeld, Krefeld, Germany.
  • Waibler HP; Institute for Heart and Circulation Research, University of Cologne, Cologne, Germany.
  • Gülker JE; Department of Cardiology, Heart Centre Niederrhein, Helios Clinics Krefeld, Krefeld, Germany.
  • Klues H; Institute for Heart and Circulation Research, University of Cologne, Cologne, Germany.
  • Bufe A; Department of Cardiology, Heart Centre Niederrhein, Helios Clinics Krefeld, Krefeld, Germany.
  • Shin DI; Institute for Heart and Circulation Research, University of Cologne, Cologne, Germany.
J Saudi Heart Assoc ; 30(4): 301-304, 2018 Oct.
Article en En | MEDLINE | ID: mdl-30069135
PURPOSE: Pulmonary vein isolation (PVI) is a cornerstone therapy in patients with symptomatic atrial fibrillation. One current method is performing a PVI using a cryoballoon (CB). The CB is inserted into the left atrium via a steerable sheath. However, at times, passing of the interatrial septum by the sheath is hindered, e.g., due to septal fibrosis. Here we report our experience with an evasion maneuver to facilitate this approach using a 6F multipolar and steerable coronary Sinus catheter (CS) for predilatation of the interatrial septum. METHODS AND RESULTS: We report 10 patients undergoing a CB-PVI, where the investigator experienced difficulties in passing the interatrial septum with the CB sheath. In these cases, after three conventional abortive attempts, we predilated the transseptal puncture site using both the CS catheter and the dilatator of the CB sheath. Thereafter access of the CB sheath to the left atrium could be achieved instantly and without further resistance. CONCLUSION: We report a safe and feasible maneuver to facilitate transseptal access with the CB steerable sheath in cases complicated by excessive interatrial resistance.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Saudi Heart Assoc Año: 2018 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Arabia Saudita

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Saudi Heart Assoc Año: 2018 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Arabia Saudita