Your browser doesn't support javascript.
loading
Dynamics of magnetization under stimulus-induced rotary saturation sequence.
Ueda, Hiroyuki; Seki, Hiroaki; Ito, Yosuke; Oida, Takenori; Taniguchi, Yo; Kobayashi, Testsuo.
Afiliación
  • Ueda H; Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-daigaku-Katsura, Nishikyo-ku, Kyoto 615-8510, Japan. Electronic address: ueda.hiroyuki.43s@st.kyoto-u.ac.jp.
  • Seki H; Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-daigaku-Katsura, Nishikyo-ku, Kyoto 615-8510, Japan.
  • Ito Y; Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-daigaku-Katsura, Nishikyo-ku, Kyoto 615-8510, Japan.
  • Oida T; Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-daigaku-Katsura, Nishikyo-ku, Kyoto 615-8510, Japan.
  • Taniguchi Y; Research & Development Group, Hitachi, Ltd., Japan.
  • Kobayashi T; Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-daigaku-Katsura, Nishikyo-ku, Kyoto 615-8510, Japan.
J Magn Reson ; 295: 38-44, 2018 Oct.
Article en En | MEDLINE | ID: mdl-30096551
ABSTRACT
We studied stimulus-induced rotary-saturation preparation (which enables measurement of oscillating magnetic fields using MRI) and derived an analytical solution of the Bloch equation to understand magnetization dynamics mathematically and comprehensively and to conduct simulations without sequential-calculation techniques such as the Runge-Kutta method. We formulated the dynamics using the Bloch equation, introducing an additional rotating frame and some approximations to make it into a homogeneous differential equation. Moreover, we found that there are two modes depending on the target oscillating magnetic field. To confirm the validity of the solution, we experimentally investigated its characteristics and performed curve fitting using the analytical model. Considering the constraints on the frame, the analytical solution was found to agree with experimental data. The experimental data indicate that it is necessary to design robust sequences compensating B0 or B1lock spatial inhomogeneity to improve measurements. Therefore, experimenters should consider the dynamics of magnetization with RF pulses to rewind the spin phase for accurate measurements.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: J Magn Reson Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: J Magn Reson Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2018 Tipo del documento: Article