Effect of Chemotherapy on Dual-Energy X-ray Absorptiometry (DXA) Body Composition Precision Error in Head and Neck Cancer Patients.
Chang, Ho-Chuen; Lin, Yu-Ching; Ng, Shu-Hang; Cheung, Yun-Chung; Wang, Cheng-Hsu; Chen, Fang-Ping; Chang, Hui-Ping; Sung, Chen-Ming; Fan, Chih-Ming; Yeh, Kun-Yun; Wu, Jim S.
Afiliación
  • Chang HC; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, Taiwan.
  • Lin YC; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, Taiwan; Keelung Osteoporosis Prevention and Treatment Center, Keelung, Taiwan.
  • Ng SH; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taiwan.
  • Cheung YC; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taiwan.
  • Wang CH; Division of Hemato-oncology, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung and Chang Gung University, College of Medicine, Keelung, Taiwan.
  • Chen FP; Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Chang Gung University, Keelung, Taiwan; Keelung Osteoporosis Prevention and Treatment Center, Keelung, Taiwan.
  • Chang HP; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, Taiwan.
  • Sung CM; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, Taiwan.
  • Fan CM; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, Taiwan.
  • Yeh KY; Division of Hemato-oncology, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung and Chang Gung University, College of Medicine, Keelung, Taiwan. Electronic address: yehtyng@gmail.com.
  • Wu JS; Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, USA.
J Clin Densitom ; 22(3): 437-443, 2019.
Article en En | MEDLINE | ID: mdl-30172603
ABSTRACT

BACKGROUND:

Precision error in dual-energy X-ray absorptiometry (DXA) is defined as difference in results due to instrumental and technical factors given no biologic change. The aim of this study is to compare precision error in DXA body composition scans in head and neck cancer patients before and 2 months after chemotherapy.

METHODOLOGY:

A total of 34 male head and neck cancer patients with normal body mass index (BMI) were prospectively enrolled and all patients received 2 consecutive DXA scans both before and after 2 months of chemotherapy for a total of 4 scans. The precision error of 3 DXA body composition values (lean mass, fat mass, and bone mineral content) was calculated for total body and 5 body regions (arms, legs, trunk, android, and gynoid). Precision errors before and after treatment were compared using generalized estimating equation model.

RESULTS:

There was no significant change in precision error for the DXA total body composition values following chemotherapy; lean mass (0.33%-0.40%, p = 0.179), total fat mass (1.39%-1.70%, p = 0.259) and total bone mineral content (0.42%-0.56%, p = 0.243). However, there were significant changes in regional precision error; trunk lean mass (1.19%-1.77%, p = 0.014) and android fat mass (2.17%-3.72%, p = 0.046).

CONCLUSIONS:

For head and neck cancer patients, precision error of DXA total body composition values did not change significantly following chemotherapy; however, there were significant changes in fat mass in the android and lean mass in the trunk. Caution should be exercised when interpreting longitudinal DXA body composition data in those body parts.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Composición Corporal / Protocolos de Quimioterapia Combinada Antineoplásica / Densidad Ósea / Tejido Adiposo / Músculo Esquelético / Quimioradioterapia / Neoplasias de Cabeza y Cuello Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans / Male / Middle aged Idioma: En Revista: J Clin Densitom Asunto de la revista: ORTOPEDIA Año: 2019 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Composición Corporal / Protocolos de Quimioterapia Combinada Antineoplásica / Densidad Ósea / Tejido Adiposo / Músculo Esquelético / Quimioradioterapia / Neoplasias de Cabeza y Cuello Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans / Male / Middle aged Idioma: En Revista: J Clin Densitom Asunto de la revista: ORTOPEDIA Año: 2019 Tipo del documento: Article País de afiliación: Taiwán