Your browser doesn't support javascript.
loading
Novel Ultrasound Image Acquisition Protocol and Scoring System for the Pediatric Knee.
Ting, Tracy V; Vega-Fernandez, Patricia; Oberle, Edward J; De Ranieri, Deirdre; Bukulmez, Hulya; Lin, Clara; Moser, David; Barrowman, Nicholas J; Zhao, Yongdong; Benham, Heather M; Tasan, Laura; Thatayatikom, Akaluck; Roth, Johannes.
Afiliación
  • Ting TV; Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
  • Vega-Fernandez P; Emory University School of Medicine and the Children's Hospital of Atlanta, Atlanta, Georgia.
  • Oberle EJ; Nationwide Children's Hospital, Columbus, Ohio.
  • De Ranieri D; Ann and Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois.
  • Bukulmez H; MetroHealth Medical Center, Cleveland, Ohio.
  • Lin C; Children's Hospital Colorado and University of Colorado Denver.
  • Moser D; Cigna, Chicago, Illinois.
  • Barrowman NJ; University of Ottawa, Ottawa, Ontario, Canada.
  • Zhao Y; Seattle Children's Hospital, Seattle, Washington.
  • Benham HM; Texas Scottish Rite Hospital for Children, Dallas, Texas.
  • Tasan L; University of Pittsburgh Medical Center Children's Hospital of Pittsburgh, Pittsburgh, Pennsylvania.
  • Thatayatikom A; University of Florida, Gainesville.
  • Roth J; Children's Hospital of Eastern Ontario, Ottawa, Ontario, Canada.
Arthritis Care Res (Hoboken) ; 71(7): 977-985, 2019 07.
Article en En | MEDLINE | ID: mdl-30192069
ABSTRACT

OBJECTIVE:

The use of musculoskeletal ultrasound is increasing among pediatric rheumatologists. Reliable scoring systems are needed for the objective assessment of synovitis. The aims of this study were to create a standardized and reproducible image acquisition protocol for B-mode and Doppler ultrasound of the pediatric knee, and to develop a standardized scoring system and determine its reliability for pediatric knee synovitis.

METHODS:

Six pediatric rheumatologists developed a set of standard views for knee assessment in children with juvenile arthritis. Subsequently, a comprehensive literature review, practical exercises, and a consensus process were performed. A scoring system for both B-mode and Doppler was then developed and assessed for reliability. Interreader reliability or agreement among a total of 16 raters was determined using 2-way single-score intraclass correlation coefficient (ICC) analysis.

RESULTS:

Twenty-one views to assess knee arthritis were initially identified. Following completion of practical exercises and subsequent consensus processes, 3 views in both B-mode and Doppler were selected suprapatellar longitudinal and medial/lateral parapatellar transverse views. Several rounds of scoring and modifications resulted in a final ICC of suprapatellar view B-mode 0.89 (95% confidence interval [95% CI] 0.86-0.92) and Doppler 0.55 (95% CI 0.41-0.69), medial parapatellar view B-mode 0.76 (95% CI 0.68-0.83) and Doppler 0.75 (95% CI 0.66-0.83), and lateral parapatellar view B-mode 0.82 (95% CI 0.75-0.88) and Doppler 0.76 (95% CI 0.66-0.84).

CONCLUSION:

A novel B-mode and Doppler image acquisition and scoring system for assessing synovitis in the pediatric knee was successfully developed through practical exercises and a consensus process. Study results demonstrate overall good-to-excellent reliability.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artritis Juvenil / Sinovitis / Ultrasonografía Doppler / Articulación de la Rodilla Tipo de estudio: Guideline / Prognostic_studies Límite: Adolescent / Child / Humans Idioma: En Revista: Arthritis Care Res (Hoboken) Asunto de la revista: REUMATOLOGIA Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artritis Juvenil / Sinovitis / Ultrasonografía Doppler / Articulación de la Rodilla Tipo de estudio: Guideline / Prognostic_studies Límite: Adolescent / Child / Humans Idioma: En Revista: Arthritis Care Res (Hoboken) Asunto de la revista: REUMATOLOGIA Año: 2019 Tipo del documento: Article
...