Your browser doesn't support javascript.
loading
Double Notched Long-Period Fiber Grating Characterization for CO2 Gas Sensing Applications †.
Hsu, Hsiang-Chang; Hsieh, Tso-Sheng; Huang, Tzu-Hsuan; Tsai, Liren; Chiang, Chia-Chin.
Afiliación
  • Hsu HC; Department of Mechanical Engineering, National Kaohsiung University of Sciences and Technology, NO.415 Jian-gong Road, Kaohsiung, Kaohsiung City 80778, Taiwan. gn1204774@gmail.com.
  • Hsieh TS; Department of Mechanical Engineering, National Kaohsiung University of Sciences and Technology, NO.415 Jian-gong Road, Kaohsiung, Kaohsiung City 80778, Taiwan. srcx2s904@gmail.com.
  • Huang TH; Department of Mechanical Engineering, National Kaohsiung University of Sciences and Technology, NO.415 Jian-gong Road, Kaohsiung, Kaohsiung City 80778, Taiwan. iamjohnny825@gmail.com.
  • Tsai L; Department of Mechanical Engineering, National Kaohsiung University of Sciences and Technology, NO.415 Jian-gong Road, Kaohsiung, Kaohsiung City 80778, Taiwan. liren@nkust.edu.tw.
  • Chiang CC; Department of Mechanical Engineering, National Kaohsiung University of Sciences and Technology, NO.415 Jian-gong Road, Kaohsiung, Kaohsiung City 80778, Taiwan. ccchiang@kuas.edu.tw.
Sensors (Basel) ; 18(10)2018 Sep 22.
Article en En | MEDLINE | ID: mdl-30248989
ABSTRACT
In this study, we applied a double-sided inductively coupled plasma (ICP) process to nanostructure long-period fiber grating (LPFG) in order to fabricate a double-notched LPFG (DNLPFG) sensor with a double-sided surface corrugated periodic grating. Using the sol-gel method, we also added thymol blue and ZnO to form a gas sensing layer, thus producing a DNLPFG CO2 gas sensor. The resulting sensor is the first double-sided etching sensor used to measure CO2. The experimental results showed that as the CO2 concentration increased, the transmission loss increased, and that the smaller the fiber diameter, the greater the sensitivity and the greater the change in transmission loss. When the diameter of the fiber was 32 µm (and the period was 570 µm) and the perfusion rate of CO2 gas was 15%, the maximum loss variation of up to 3.881 dB was achieved, while the sensitivity was 0.2146 dB/% and the linearity was 0.992. These results demonstrate that the DNLPG CO2 gas sensor is highly sensitive.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sensors (Basel) Año: 2018 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sensors (Basel) Año: 2018 Tipo del documento: Article País de afiliación: Taiwán
...