Your browser doesn't support javascript.
loading
Diagnostic capacity of electron cyclotron emission imaging system with continuous large observation area on EAST tokamak.
Gao, BingXi; Xie, JinLin; Zhao, ZhenLing; Qu, Chengming; Liao, Wang; Xu, Xinhang; Mao, WenZhe; Zhuang, Ge; Liu, WanDong.
Afiliación
  • Gao B; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Xie J; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Zhao Z; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Qu C; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Liao W; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Xu X; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Mao W; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Zhuang G; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
  • Liu W; School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
Rev Sci Instrum ; 89(9): 093503, 2018 Sep.
Article en En | MEDLINE | ID: mdl-30278762
ABSTRACT
Electron cyclotron emission imaging on EAST provides direct measurements of the 2-D electron temperature dynamics in a continuous large observation area with high temporal and spatial resolution. Besides the normal MHD investigation, a system with a view field large enough to cover the core plasma region has been applied to extract more plasma information, such as the plasma center location, the deposition location of auxiliary heating, and the core toroidal rotation speed. These results solely based on electron cyclotron emission imaging (ECEI) data are consistent with the results of the equilibrium fitting (EFIT), numerical code, and other diagnostics, which indicate the powerful diagnostic capacity of this ECEI system.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article