Your browser doesn't support javascript.
loading
Smartphone-based differential pulse amperometry system for real-time monitoring of levodopa with carbon nanotubes and gold nanoparticles modified screen-printing electrodes.
Ji, Daizong; Xu, Ning; Liu, Zixiang; Shi, Zhouyuanjing; Low, Sze Shin; Liu, Jingjing; Cheng, Chen; Zhu, Jingwen; Zhang, Tingkai; Xu, Haoxuan; Yu, Xiongjie; Liu, Qingjun.
Afiliación
  • Ji D; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China; Zhejiang University Interdisciplinary Institute of Neuroscience and Technology, Qiushi Academy for Advanced St
  • Xu N; Institute of Automation Engineering, Northeast Electric Power University, Jilin 132012, PR China.
  • Liu Z; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China.
  • Shi Z; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China.
  • Low SS; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China.
  • Liu J; Institute of Automation Engineering, Northeast Electric Power University, Jilin 132012, PR China.
  • Cheng C; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China; Collaborative Innovation Center of TCM Health Management, Fujian University of Traditional Chinese Medicine, F
  • Zhu J; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China.
  • Zhang T; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China.
  • Xu H; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China.
  • Yu X; Zhejiang University Interdisciplinary Institute of Neuroscience and Technology, Qiushi Academy for Advanced Studies, Zhejiang University, Hangzhou, Zhejiang Province, PR China.
  • Liu Q; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China; Collaborative Innovation Center of TCM Health Management, Fujian University of Traditional Chinese Medicine, F
Biosens Bioelectron ; 129: 216-223, 2019 Mar 15.
Article en En | MEDLINE | ID: mdl-30297172
ABSTRACT
Parkinson's disease caused by lack of dopamine in brain is a common neurodegenerative disorder. The traditional treatment is to replenish levodopa since it could pass through blood brain barrier and form dopamine. However, its accumulation can cause patients' movement disorders and uncontrollable emotion. Therefore, it is critical to control the levodopa dosage accuracy to improve the curative effect in clinical. In this study, a smartphone-based electrochemical detection system was developed for rapid monitoring of levodopa. The system involved a disposable sensor, a hand-held electrochemical detector, and a smartphone with designed application. Single-wall carbon nanotubes and gold nanoparticles modified screen-printed electrodes were used to convert and amplify the electrochemical current signals upon presence of levodopa molecules. The electrochemical detectors were used to generate electrochemical excitation signals and detect the resultant currents. Smartphone was connected to the detector, which was used to control the detector, calculate data, and plot graph in real-time. The smartphone-based differential pulse amperometry system was demonstrated to monitor levodopa at concentrations as low as 0.5 µM in human serum. Furthermore, it has also been verified to be able to distinguish levodopa from other representative substances in the body. Therefore, its performance was more sensitive and rapid than electrochemical workstation. With these advantages, the system can be used in the field of point-of-care testing (POCT) to detect levodopa and provide the possibility to solve clinical demand for levodopa detection.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Levodopa / Nanotubos de Carbono / Nanopartículas del Metal / Técnicas Electroquímicas / Oro / Antiparkinsonianos Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2019 Tipo del documento: Article Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Levodopa / Nanotubos de Carbono / Nanopartículas del Metal / Técnicas Electroquímicas / Oro / Antiparkinsonianos Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2019 Tipo del documento: Article Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM