Benefits of Cochlear Implantation for Single-Sided Deafness: Data From the House Clinic-University of Southern California-University of California, Los Angeles Clinical Trial.
Galvin, John J; Fu, Qian-Jie; Wilkinson, Eric P; Mills, Dawna; Hagan, Suzannah C; Lupo, J Eric; Padilla, Monica; Shannon, Robert V.
Afiliación
  • Galvin JJ; Auditory Implants Department, House Ear Institute, Los Angeles, CA, USA.
  • Fu QJ; Department of Head and Neck Surgery, David Geffen School of Medicine, University of California, Los Angeles, CA, USA.
  • Wilkinson EP; Department of Head and Neck Surgery, David Geffen School of Medicine, University of California, Los Angeles, CA, USA.
  • Mills D; Auditory Implants Department, House Ear Institute, Los Angeles, CA, USA.
  • Hagan SC; House Clinic, Los Angeles, CA, USA.
  • Lupo JE; House Clinic, Los Angeles, CA, USA.
  • Padilla M; House Clinic, Los Angeles, CA, USA.
  • Shannon RV; House Clinic, Los Angeles, CA, USA.
Ear Hear ; 40(4): 766-781, 2019.
Article en En | MEDLINE | ID: mdl-30358655
ABSTRACT

OBJECTIVES:

Cochlear implants (CIs) have been shown to benefit patients with single-sided deafness (SSD) in terms of tinnitus reduction, localization, speech understanding, and quality of life (QoL). While previous studies have shown cochlear implantation may benefit SSD patients, it is unclear which point of comparison is most relevant baseline performance before implantation versus performance with normal-hearing (NH) ear after implantation. In this study, CI outcomes were assessed in SSD patients before and up to 6 mo postactivation. Benefits of cochlear implantation were assessed relative to binaural performance before implantation or relative to performance with the NH ear alone after implantation.

DESIGN:

Here, we report data for 10 patients who completed a longitudinal, prospective, Food and Drug Administration-approved study of cochlear implantation for SSD patients. All subjects had severe to profound unilateral hearing loss in one ear and normal hearing in the other ear. All patients were implanted with the MED-EL CONCERTO Flex 28 device. Speech understanding in quiet and in noise, localization, and tinnitus severity (with the CI on or off) were measured before implantation (baseline) and at 1, 3, 6 mo postactivation of the CI processor. Performance was measured with both ears (binaural), the CI ear alone, and the NH ear alone (the CI ear was plugged and muffed). Tinnitus severity, dizziness severity, and QoL were measured using questionnaires administered before implantation and 6 mo postactivation.

RESULTS:

Significant CI benefits were observed for tinnitus severity, localization, speech understanding, and QoL. The degree and time course of CI benefit depended on the outcome measure and the reference point. Relative to binaural baseline performance, significant and immediate (1 mo postactivation) CI benefits were observed for tinnitus severity and speech performance in noise, but localization did not significantly improve until 6 mo postactivation; questionnaire data showed significant improvement in QoL 6 mo postactivation. Relative to NH-only performance after implantation, significant and immediate benefits were observed for tinnitus severity and localization; binaural speech understanding in noise did not significantly improve during the 6-mo study period, due to variability in NH-only performance. There were no correlations between behavioral and questionnaire data, except between tinnitus visual analog scale scores at 6 mo postactivation and Tinnitus Functional Index scores at 6 mo postactivation.

CONCLUSIONS:

The present behavioral and subjective data suggest that SSD patients greatly benefit from cochlear implantation. However, to fully understand the degree and time course of CI benefit, the outcome measure and point of comparison should be considered. From a clinical perspective, binaural baseline performance is a relevant point of comparison. The lack of correlation between behavioral and questionnaire data suggest that represent independent measures of CI benefit for SSD patients.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Calidad de Vida / Localización de Sonidos / Percepción del Habla / Acúfeno / Implantación Coclear / Pérdida Auditiva Unilateral Tipo de estudio: Observational_studies Aspecto: Patient_preference Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ear Hear Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Calidad de Vida / Localización de Sonidos / Percepción del Habla / Acúfeno / Implantación Coclear / Pérdida Auditiva Unilateral Tipo de estudio: Observational_studies Aspecto: Patient_preference Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ear Hear Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos