Removal capacity of different high-flux dialyzers during postdilution online hemodiafiltration.
Santos García, Alba; Macías Carmona, Nicolás; Vega Martínez, Almudena; Abad Estébanez, Soraya; Linares Grávalos, Tania; Aragoncillo Sauco, Inés; Verdalles Guzmán, Ursula; Panizo González, Nayara; Cruzado Vega, Leonidas; López Gómez, Juan Manuel.
Afiliación
  • Santos García A; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Macías Carmona N; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Vega Martínez A; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Abad Estébanez S; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Linares Grávalos T; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Aragoncillo Sauco I; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Verdalles Guzmán U; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Panizo González N; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
  • Cruzado Vega L; Nephrology Department, Hospital Universitario de Elche, Alicante, Spain.
  • López Gómez JM; Nephrology Department, Hospital Gregorio Marañón, Madrid, Spain.
Hemodial Int ; 23(1): 50-57, 2019 01.
Article en En | MEDLINE | ID: mdl-30367698
INTRODUCTION: The aim of this study is to compare molecule removal and albumin leakage in postdilution online hemodiafiltration with different high-flux dialyzers. METHODS: We studied seven high-flux dialyzers (Polyflux 210H®, Evodial 2.2®, FxCordiax1000®, Elisio21H®, TS-2.1SL®, XevontaHi20®, VitaPES 210-HF®) in 6 patients. The reduction ratio (RR) of small- and middle-sized molecules was calculated. Dialysate samples were collected to estimate the albumin leakage. FINDINGS: Global differences between dialyzers were observed in the RR of ß2 microglobulin (P =0.003) and prolactin (P =0.013). The mean loss of albumin in the dialysate per session varied between 114 ± 67 mg (with Evodial 2.2) and 2621 ± 1363 mg per session (with XevontaHi20). We found global differences between dialyzers in total albumin loss (P = 0.05). DISCUSSION: We demonstrated that the performance of high-flux dialyzers was different among the types and that not all high-flux dialyzers should be considered equal.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Soluciones para Diálisis / Diálisis Renal / Hemodiafiltración Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Hemodial Int Asunto de la revista: NEFROLOGIA / TERAPEUTICA Año: 2019 Tipo del documento: Article País de afiliación: España Pais de publicación: Canadá

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Soluciones para Diálisis / Diálisis Renal / Hemodiafiltración Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Hemodial Int Asunto de la revista: NEFROLOGIA / TERAPEUTICA Año: 2019 Tipo del documento: Article País de afiliación: España Pais de publicación: Canadá