OBJECTIVES:

  To evaluate and compare the performances of new types of supraglottic airway devices (SADs) with endotracheal intubation regarding their ease of insertions, perioperative complications, and effects on hemodynamic parameters and peak airway pressures in laparascopic cholecystectomy (LC).  

Methods:

One hundred and fourteen patients with ASA 1-2 physical status scheduled for elective LC were recruited for this prospective randomized controlled trial. The study was completed between January  2016 and January 2017 in Adiyaman University Research and Educational Hospital, Adiyaman, Turkey. The patients were divided into AuraGain(Ambu, Ballerup, Denmark) (n=38), i-Gel® (Intersurgical Ltd, UK) (n=35), and endotracheal tube (ETT)(n=32) groups. Ease of insertion, airway pressures, complications, and hemodynamic variables were compared. 

Results:

The trial was completed with 105 patients. Ease of insertion for SADs which was evaluated with insertion procedure duration, attempts, first insertion success rates, and oropharyngeal leak pressures were similar between the groups. Heart rate, systolic and diastolic arterial pressures, and peak airway pressures were significantly lower in the AuraGain and i-Gel® groups, compared with the ETT, p less than 0.017. 

Conclusion:

Both AuraGain and i-Gel® SADs are comparable with ETT used for airway control in general anesthesia for LC, regarding application ease and perioperative complications. Favorable hemodynamic responses to AuraGain and i-Gel® SADs may put them in a better place than ETT.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Máscaras Laríngeas / Colecistectomía Laparoscópica / Anestesia General Tipo de estudio: Clinical_trials / Evaluation_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Saudi Med J Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Máscaras Laríngeas / Colecistectomía Laparoscópica / Anestesia General Tipo de estudio: Clinical_trials / Evaluation_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Saudi Med J Año: 2018 Tipo del documento: Article
...