Your browser doesn't support javascript.
loading
The surface eroding thermocouple for fast heat flux measurement in DIII-D.
Ren, J; Donovan, D; Watkins, J; Wang, H Q; Rudakov, D; Murphy, C; McLean, A; Lasnier, C; Unterberg, E; Thomas, D; Boivin, R.
Afiliación
  • Ren J; University of Tennessee, Knoxville, Knoxville, Tennessee 37996-1410, USA.
  • Donovan D; University of Tennessee, Knoxville, Knoxville, Tennessee 37996-1410, USA.
  • Watkins J; Sandia National Laboratories, Livermore, California 94551, USA.
  • Wang HQ; Oak Ridge Associated Universities, Oak Ridge, Tennessee 37830, USA.
  • Rudakov D; University of California San Diego, San Diego, California 92093, USA.
  • Murphy C; General Atomics, San Diego, California 92186-5608, USA.
  • McLean A; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Lasnier C; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Unterberg E; Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830, USA.
  • Thomas D; General Atomics, San Diego, California 92186-5608, USA.
  • Boivin R; General Atomics, San Diego, California 92186-5608, USA.
Rev Sci Instrum ; 89(10): 10J122, 2018 Oct.
Article en En | MEDLINE | ID: mdl-30399945
A novel type of surface eroding thermocouple (SETC) has been tested and demonstrated in the small angle slot (SAS) divertor of DIII-D for fast local heat flux measurements. The thermojunction of the SETC is formed between two thin (10 µm) ribbons, which are filed over to create microfiber junctions. These thermocouples are able to be exposed directly to the plasma at surface temperatures exceeding 2000 °C and are capable of sub-10 ms time resolution. Before installation in SAS, the SETCs were exposed in the lower DIII-D divertor during L-mode and H-mode discharges, from which results are presented. In preliminary tests, SETCs proved to be a qualified diagnostic to accurately measure both the intra-edge localized mode (ELM) and inter-ELM heat flux during H-mode shots with high frequency ELMs (hundreds of Hz) and to resolve heat flux profiles during strike point sweeps. The heat fluxes measured by using SETCs are consistent with the heat fluxes measured by using IR cameras and Langmuir probes. These new diagnostic capabilities will complement the existing IR camera measurements and will be of particularly significant value to measure surface heat flux in the SAS divertor or other regions where the IR camera lacks line of sight.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos