Your browser doesn't support javascript.
loading
Reliability of fast magnetic resonance imaging for acute ischemic stroke patients using a 1.5-T scanner.
Chung, Mi Sun; Lee, Ji Ye; Jung, Seung Chai; Baek, Seunghee; Shim, Woo Hyun; Park, Ji Eun; Kim, Ho Sung; Choi, Choong Gon; Kim, Sang Joon; Lee, Deok Hee; Jeon, Sang-Beom; Kang, Dong-Wha; Kwon, Sun U; Kim, Jong S.
Afiliación
  • Chung MS; Department of Radiology, Chung-Ang University Hospital, Seoul, South Korea.
  • Lee JY; Department of Radiology, Soonchunhyang University Bucheon Hospital, Wonmi-gu, Bucheon, South Korea.
  • Jung SC; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song pa-gu, Seoul, 138-736, South Korea. dynamics79@gmail.com.
  • Baek S; Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
  • Shim WH; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song pa-gu, Seoul, 138-736, South Korea.
  • Park JE; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song pa-gu, Seoul, 138-736, South Korea.
  • Kim HS; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song pa-gu, Seoul, 138-736, South Korea.
  • Choi CG; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song pa-gu, Seoul, 138-736, South Korea.
  • Kim SJ; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song pa-gu, Seoul, 138-736, South Korea.
  • Lee DH; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song pa-gu, Seoul, 138-736, South Korea.
  • Jeon SB; Department of Neurology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
  • Kang DW; Department of Neurology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
  • Kwon SU; Department of Neurology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
  • Kim JS; Department of Neurology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
Eur Radiol ; 29(5): 2641-2650, 2019 May.
Article en En | MEDLINE | ID: mdl-30421013
ABSTRACT

OBJECTIVES:

To determine whether fast scanned MRI using a 1.5-T scanner is a reliable method for the detection and characterization of acute ischemic stroke in comparison with conventional MRI.

METHODS:

From May 2015 to June 2016, 862 patients (FLAIR, n = 482; GRE, n = 380; MRA, n = 190) were prospectively enrolled in the study, with informed consent and under institutional review board approval. The patients underwent both fast (EPI-FLAIR, ETL-FLAIR, TR-FLAIR, EPI-GRE, parallel-GRE, fast CE-MRA) and conventional MRI (FLAIR, GRE, time-of-flight MRA, fast CE-MRA). Two neuroradiologists independently assessed agreements in acute and chronic ischemic hyperintensity, hyperintense vessels (FLAIR), microbleeds, susceptibility vessel signs, hemorrhagic transformation (GRE), stenosis (MRA), and image quality (all MRI), between fast and conventional MRI. Agreements between fast and conventional MRI were evaluated by generalized estimating equations. Z-scores were used for comparisons of the percentage agreement among fast FLAIR sequences and fast GRE sequences and between conventional and fast MRA.

RESULTS:

Agreements of more than 80% were achieved between fast and conventional MRI (ETL-FLAIR, 96%; TR-FLAIR, 97%; EPI-GRE, 96%; parallel-GRE, 98%; fast CE-MRA, 86%). ETL- and TR-FLAIR were significantly superior to EPI-FLAIR in the detection of acute ischemic hyperintensity and hyperintense vessels, while parallel-GRE was significantly superior to EPI-GRE in the detection of susceptibility vessel sign (p value < 0.05 for all). There were no significant differences in the other scores and image qualities (p value > 0.05).

CONCLUSIONS:

Fast MRI at 1.5 T is a reliable method for the detection and characterization of acute ischemic stroke in comparison with conventional MRI. KEY POINTS • Fast MRI at 1.5 T may achieve a high intermethod reliability in the detection and characterization of acute ischemic stroke with a reduction in scan time in comparison with conventional MRI.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Encéfalo / Imagen por Resonancia Magnética / Isquemia Encefálica Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Corea del Sur

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Encéfalo / Imagen por Resonancia Magnética / Isquemia Encefálica Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2019 Tipo del documento: Article País de afiliación: Corea del Sur
...