Your browser doesn't support javascript.
loading
Clinical relevance of protruded retinal layers in minimum rim width measurement of the optic nerve head.
Torres, Lucas A; Jarrar, Faisal; Sharpe, Glen P; Hutchison, Donna M; Ferracioli-Oda, Eduardo; Hatanaka, Marcelo; Nicolela, Marcelo T; Vianna, Jayme R; Chauhan, Balwantray C.
Afiliación
  • Torres LA; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Dalhousie, Canada.
  • Jarrar F; Department of Ophthalmology, University of São Paulo School of Medicine, São Paulo, Brazil.
  • Sharpe GP; Faculty of Medicine, Dalhousie University, Halifax, Dalhousie, Canada.
  • Hutchison DM; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Dalhousie, Canada.
  • Ferracioli-Oda E; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Dalhousie, Canada.
  • Hatanaka M; Department of Ophthalmology, University of São Paulo School of Medicine, São Paulo, Brazil.
  • Nicolela MT; Department of Ophthalmology, University of São Paulo School of Medicine, São Paulo, Brazil.
  • Vianna JR; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Dalhousie, Canada.
  • Chauhan BC; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Dalhousie, Canada.
Br J Ophthalmol ; 103(10): 1401-1405, 2019 10.
Article en En | MEDLINE | ID: mdl-30472658
ABSTRACT
BACKGROUND/

AIMS:

Optical coherence tomography (OCT) imaging of the optic nerve head minimum rim width (MRW) has recently been shown to sometimes contain components besides extended retinal nerve fibre layer (RNFL). This study was conducted to determine whether excluding these components, termed protruded retinal layers (PRLs), from MRW increases diagnostic accuracy for detecting glaucoma.

METHODS:

In this cross-sectional study, we included 123 patients with glaucoma and 123 normal age-similar controls with OCT imaging of the optic nerve head (24 radial scans) and RNFL (circle scan). When present, PRLs were manually segmented, and adjusted MRW measurements were computed. We compared diagnostic accuracy of adjusted versus unadjusted MRW measurement. We also determined whether adjusted MRW correlates better with RNFL thickness compared with unadjusted MRW.

RESULTS:

The median (IQR) visual field mean deviation of patients and controls was -4.4 (-10.3 to -2.1) dB and 0.0 (-0.6 to 0.8) dB, respectively. In the 5904 individual B-scans, PRLs were identified less frequently in patients (448, 7.6%) compared with controls (728, 12.3%; p<0.01) and were present most frequently in the temporal sector of both groups. Areas under the receiver operating characteristic curves and sensitivity values at 95% specificity indicated that PRL adjustment did not improve diagnostic accuracy of MRW, globally or temporally. Furthermore, adjusting MRW for PRL did not improve its correlation with RNFL thickness in either group.

CONCLUSION:

While layers besides the RNFL are sometimes included in OCT measurements of MRW, subtracting these layers does not impact clinical utility.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Células Ganglionares de la Retina / Glaucoma de Ángulo Abierto / Fibras Nerviosas Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Ophthalmol Año: 2019 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Disco Óptico / Células Ganglionares de la Retina / Glaucoma de Ángulo Abierto / Fibras Nerviosas Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Ophthalmol Año: 2019 Tipo del documento: Article País de afiliación: Canadá
...