Your browser doesn't support javascript.
loading
Comparison of Pure-Tone Average Methods for Estimation of Hearing Loss Caused by Environmental Exposure to Lead and Cadmium: Does the Pure-Tone Average Method Which Uses Low-Frequency Ranges Underestimate the Actual Hearing Loss Caused by Environmental Lead and Cadmium Exposure?
Huh, Da-An; Choi, Yun-Hee; Ji, Myung Sun; Moon, Kyong Whan; Yoon, Seok J; Sohn, Jong-Ryeul.
Afiliación
  • Huh DA; Department of Public Health Sciences, Graduate School, Korea University, Seoul, Republic of Korea.
  • Choi YH; Department of Health and Safety Convergence Science, Graduate School, Korea University, Seoul, Republic of Korea.
  • Ji MS; Department of Health and Environmental Science, College of Health Science, Korea University, Seoul, Republic of Korea.
  • Moon KW; Department of Health and Environmental Science, College of Health Science, Korea University, Seoul, Republic of Korea, kwmoon@korea.ac.kr.
  • Yoon SJ; BK21 PLUS Program in Embodiment: Health-Society Interaction, Department of Public Health Sciences, Graduate School, Korea University, Seoul, Republic of Korea.
  • Sohn JR; BK21 PLUS Program in Embodiment: Health-Society Interaction, Department of Public Health Sciences, Graduate School, Korea University, Seoul, Republic of Korea.
Audiol Neurootol ; 23(5): 259-269, 2018.
Article en En | MEDLINE | ID: mdl-30537721
ABSTRACT
Previous studies have reported that exposure to lead and cadmium can damage the inner ear receptor, which perceives high-frequency sounds. However, few studies have used the pure-tone average (PTA), including high-frequency ranges, for the estimation of hearing loss caused by lead and cadmium exposure. We estimated hearing loss using the PTA test, in low-frequency, speech frequency, and high-frequency ranges and compared the differences in the results using 3 PTA calculation methods. We analyzed the data of 2,387 participants, between the ages of 19 and 85 years, that were obtained from the Korea National Health and Nutrition Examination Survey (KNHANES) of 2010-2012. A dose-response relationship between hearing loss and heavy metal exposure was observed in the high-frequency method after adjustment for confounding factors. When using the high-frequency PTA, it was found that doubling of the levels of lead and cadmium in the blood was associated with a 1.88- (95% CI 1.11-3.17) and 1.89-fold (95% CI 1.02-3.50) increase in the OR for hearing loss. In the case of the low-frequency and speech frequency PTA, however, there were no significant relationships between hearing loss and the concentrations of lead and cadmium in the blood. The outcomes of the present study suggest that the estimation of hearing loss caused by environmental exposure to lead and cadmium is affected by the frequencies used in the PTA calculation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Audiometría de Tonos Puros / Cadmio / Exposición a Riesgos Ambientales / Pérdida Auditiva / Plomo Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Audiol Neurootol Asunto de la revista: AUDIOLOGIA / PSICOFISIOLOGIA Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Audiometría de Tonos Puros / Cadmio / Exposición a Riesgos Ambientales / Pérdida Auditiva / Plomo Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Audiol Neurootol Asunto de la revista: AUDIOLOGIA / PSICOFISIOLOGIA Año: 2018 Tipo del documento: Article