Your browser doesn't support javascript.
loading
A comparison of valve-in-valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves.
Choi, Charles H; Cheng, Vivian; Malaver, Diego; Kon, Neal; Kincaid, Edward H; Gandhi, Sanjay K; Applegate, Robert J; Zhao, David X M.
Afiliación
  • Choi CH; Section of Cardiovascular Medicine, Department of Internal Medicine, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Cheng V; Section of Cardiovascular Medicine, Department of Internal Medicine, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Malaver D; Section of Cardiovascular Medicine, Department of Internal Medicine, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Kon N; Department of Cardiothoracic Surgery, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Kincaid EH; Department of Cardiothoracic Surgery, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Gandhi SK; Section of Cardiovascular Medicine, Department of Internal Medicine, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Applegate RJ; Section of Cardiovascular Medicine, Department of Internal Medicine, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
  • Zhao DXM; Section of Cardiovascular Medicine, Department of Internal Medicine, Wake Forest University Baptist Medical Center, Wake Forest University School of Medicine, Winston-Salem, North Carolina.
Catheter Cardiovasc Interv ; 93(6): 1106-1115, 2019 05 01.
Article en En | MEDLINE | ID: mdl-30588736

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Bioprótesis / Falla de Prótesis / Prótesis Valvulares Cardíacas / Stents / Implantación de Prótesis de Válvulas Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Bioprótesis / Falla de Prótesis / Prótesis Valvulares Cardíacas / Stents / Implantación de Prótesis de Válvulas Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2019 Tipo del documento: Article