Your browser doesn't support javascript.
loading
Machine learning derived segmentation of phase velocity encoded cardiovascular magnetic resonance for fully automated aortic flow quantification.
Bratt, Alex; Kim, Jiwon; Pollie, Meridith; Beecy, Ashley N; Tehrani, Nathan H; Codella, Noel; Perez-Johnston, Rocio; Palumbo, Maria Chiara; Alakbarli, Javid; Colizza, Wayne; Drexler, Ian R; Azevedo, Clerio F; Kim, Raymond J; Devereux, Richard B; Weinsaft, Jonathan W.
Afiliación
  • Bratt A; Department of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Kim J; Department of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Pollie M; Greenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Beecy AN; Greenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Tehrani NH; Greenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Codella N; Greenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Perez-Johnston R; IBM TJ Watson Research Center, 1101 Kitchawan Rd, Yorktown Heights, NY, 10598, USA.
  • Palumbo MC; Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY, 10065, USA.
  • Alakbarli J; Greenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Colizza W; Greenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Drexler IR; Department of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Azevedo CF; Department of Radiology, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
  • Kim RJ; Duke Cardiovascular Magnetic Resonance Center, 10 Duke Medicine Circle, Durham, NC, 27710, USA.
  • Devereux RB; Duke Cardiovascular Magnetic Resonance Center, 10 Duke Medicine Circle, Durham, NC, 27710, USA.
  • Weinsaft JW; Greenberg Division of Cardiology, Department of Medicine, Weill Cornell Medicine, 525 E 68th St, New York, NY, 10065, USA.
J Cardiovasc Magn Reson ; 21(1): 1, 2019 01 07.
Article en En | MEDLINE | ID: mdl-30612574
ABSTRACT

BACKGROUND:

Phase contrast (PC) cardiovascular magnetic resonance (CMR) is widely employed for flow quantification, but analysis typically requires time consuming manual segmentation which can require human correction. Advances in machine learning have markedly improved automated processing, but have yet to be applied to PC-CMR. This study tested a novel machine learning model for fully automated analysis of PC-CMR aortic flow.

METHODS:

A machine learning model was designed to track aortic valve borders based on neural network approaches. The model was trained in a derivation cohort encompassing 150 patients who underwent clinical PC-CMR then compared to manual and commercially-available automated segmentation in a prospective validation cohort. Further validation testing was performed in an external cohort acquired from a different site/CMR vendor.

RESULTS:

Among 190 coronary artery disease patients prospectively undergoing CMR on commercial scanners (84% 1.5T, 16% 3T), machine learning segmentation was uniformly successful, requiring no human intervention Segmentation time was < 0.01 min/case (1.2 min for entire dataset); manual segmentation required 3.96 ± 0.36 min/case (12.5 h for entire dataset). Correlations between machine learning and manual segmentation-derived flow approached unity (r = 0.99, p < 0.001). Machine learning yielded smaller absolute differences with manual segmentation than did commercial automation (1.85 ± 1.80 vs. 3.33 ± 3.18 mL, p < 0.01) Nearly all (98%) of cases differed by ≤5 mL between machine learning and manual methods. Among patients without advanced mitral regurgitation, machine learning correlated well (r = 0.63, p < 0.001) and yielded small differences with cine-CMR stroke volume (∆ 1.3 ± 17.7 mL, p = 0.36). Among advanced mitral regurgitation patients, machine learning yielded lower stroke volume than did volumetric cine-CMR (∆ 12.6 ± 20.9 mL, p = 0.005), further supporting validity of this method. Among the external validation cohort (n = 80) acquired using a different CMR vendor, the algorithm yielded equivalently small differences (∆ 1.39 ± 1.77 mL, p = 0.4) and high correlations (r = 0.99, p < 0.001) with manual segmentation, including similar results in 20 patients with bicuspid or stenotic aortic valve pathology (∆ 1.71 ± 2.25 mL, p = 0.25).

CONCLUSION:

Fully automated machine learning PC-CMR segmentation performs robustly for aortic flow quantification - yielding rapid segmentation, small differences with manual segmentation, and identification of differential forward/left ventricular volumetric stroke volume in context of concomitant mitral regurgitation. Findings support use of machine learning for analysis of large scale CMR datasets.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta / Válvula Aórtica / Imagen por Resonancia Cinemagnética / Imagen de Perfusión Miocárdica / Aprendizaje Automático / Cardiopatías / Hemodinámica Tipo de estudio: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: America do norte Idioma: En Revista: J Cardiovasc Magn Reson Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta / Válvula Aórtica / Imagen por Resonancia Cinemagnética / Imagen de Perfusión Miocárdica / Aprendizaje Automático / Cardiopatías / Hemodinámica Tipo de estudio: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: America do norte Idioma: En Revista: J Cardiovasc Magn Reson Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos