Your browser doesn't support javascript.
loading
Vibration Mitigation Effect Investigation of a New Slab Track Plate Design.
Liu, Linya; Wang, Xuan; Zhou, Yun-Lai; Qin, Jialiang.
Afiliación
  • Liu L; Engineering Research Center of Railway Environment Vibration and Noise Ministry of Education, East China Jiaotong University, Nanchang 330013, China. lly@ecjtu.edu.cn.
  • Wang X; Engineering Research Center of Railway Environment Vibration and Noise Ministry of Education, East China Jiaotong University, Nanchang 330013, China. 2016018082301009@ecjtu.jx.cn.
  • Zhou YL; Department of Civil and Environmental Engineering, National University of Singapore, Singapore 117576, Singapore. yunlai.zhou@alumnos.upm.es.
  • Qin J; Engineering Research Center of Railway Environment Vibration and Noise Ministry of Education, East China Jiaotong University, Nanchang 330013, China. 2015018082301012@ecjtu.jx.cn.
Sensors (Basel) ; 19(1)2019 Jan 05.
Article en En | MEDLINE | ID: mdl-30621256
This study proposed a novel vibration mitigation slab track plate design to mitigate the vibration induced in urban rail transit operations. The optimal recipe for the newly designed slab track plate is obtained by a series of laboratory tests, and both newly designed vibration mitigation slab track plates and normal slab track plates are fabricated and hereinafter tested. The newly designed slab track plate was examined with a series of laboratory tests in comparison with the normal slab track plate. The PolyMAX method is then adopted for extracting the modal properties, including resonant frequencies, and damping ratios are also determined for both the designed slab and normal slab track plates. A vibration mitigation level (Ls) is defined to address the vibration mitigation performance taking the acceleration response of the normal slab track plate as reference. The newly designed slab track plate demonstrated better dynamic and damping characteristics in comparison with the normal slab track plate. Under the same excitation force, the newly designed slab track plate can mitigate 8.9 dB on average in the frequency range [20, 400] Hz, expressing the feasibility of effective vibration mitigation capacity.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sensors (Basel) Año: 2019 Tipo del documento: Article País de afiliación: China Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sensors (Basel) Año: 2019 Tipo del documento: Article País de afiliación: China Pais de publicación: Suiza